Used Gulf Coast Environmental Process Equipment
Stock No.:
54110001Used Gulf Coast Exchanger Shell & Tube Heat Exchanger | 1733 Sq. Ft. | 300 PSI | U-Tube | 2017
Used Gulf Coast Exchanger Shell & Tube Heat Exchanger | 1733 Sq. Ft. | 300 PSI | U-Tube | 2017; SA-789 U-tube construction; SA-516-70 shell construction. 300 psig shell side design pressure; Full vacuum pressure; 390 psig shell side test pressure; 500 degrees F shell side design temp.; -20 degrees F shell MDMT; 1 pass shell side. 300 psig tube side design pressure; Full vacuum pressure; 390 psig tube side test pressure; 500 degrees F tube side design temp.; -20 degrees F MDMT; 2 pass tube side. (306) U-tubes .75" OD x approx. 13'3" straight length. OAD: 35.25" D x approx. 215.5" L. SN 824114, NB #103. Built 2017.
MFR: Gulf Coast Environmental