Used Stainless Steel Shell & Tube Heat Exchangers for Sale
Shell and tube heat exchangers are industrial thermal transfer systems designed to efficiently transfer heat between two fluids using a bundle of tubes enclosed within a cylindrical shell. Stainless steel shell and tube heat exchangers are specifically engineered for applications requiring corrosion resistance, sanitary conditions, and durability in demanding environments. Used stainless steel shell and tube heat exchangers are widely used in chemical processing, food and beverage production, pharmaceuticals, and energy systems. Aaron Equipment offers used stainless steel shell and tube heat exchangers for sale in a range of sizes, pressure ratings, and configurations to meet diverse process requirements.
Stock No.:
54234016Used Xylem Shell & Tube Heat Exchanger – 150 PSI Pressure Rating, Built 2018
Used Xylem "U-Tube" Heat Exchanger, Approximately 78 Square Foot, Horizontal. (22) 304 Stainless steel 3/4" diameter. Shell and tubes rated 150 psi @ -20 to 375 Degrees F. Approximate 8" diameter x 108" long carbon steel shell, with sheathing. Openings: Shell (2) 2" diameter, Tube (2) 2" diameter, Vent 3/4", (2) 1/2" drains. Serial# 285806-03, National Board# 314565, Built 2018. Dimensions 118" x 54" x 34"tall
Stock No.:
48291048Unused Single-Pass Shell & Tube Heat Exchanger, 8,254 Sq. Ft.
Unused- Single Pass Shell & Tube Heat Exchanger, Approximate 8254 Square Feet, Tema Type AEL, Horizontal. Carbon steel shell rated 527psi/Full Vacuum at 230 degrees F. (1952) 3/4" diameter x 264" long 2205 Duplex stainless steel tubes rated 139psi/Full Vacuum at 230 degrees F, Duplex 2205 stainless steel heads. Openings shell (2) 6", openings for tubes 20", 24". Mfg: Ilsung Corporation. Serial# 14-HE-080, National Board# 2064, built 2014. OAD 380"L X 54"W X 98"T, 44748 lbs. Documents available. Nitrogen purged by manufacturer after testing and prior to storage.
MFR: Ilsung Corporation
Stock No.:
48291049Unused- Ilsung Single Pass Shell & Tube Heat Exchanger - 8,254 sq ft
Unused- Single Pass Shell & Tube Heat Exchanger, Approximate 8254 Square Feet, Tema Type AEL, Horizontal. Carbon steel shell rated 527psi/Full Vacuum at 230 degrees F. (1952) 3/4" diameter x 264" long 2205 Duplex stainless steel tubes rated 139psi/Full Vacuum at 230 degrees F, Duplex 2205 stainless steel heads. Openings shell (2) 6", openings for tubes 20", 24". Mfg: Ilsung Corporation. Serial# 14-HE-081, National Board# 2065, built 2014. OAD 380"L X 54"W X 98"T, 44748 lbs. Documents available. Nitrogen purged by manufacturer after testing and prior to storage.
MFR: Ilsung Corporation
Stock No.:
53267102Used Southern Heat Exchanger 8500 Sq. Ft. 304L Stainless Horizontal Heat Exchanger – 51" x 26', Built 2019
Used Southern Heat Exchanger 8500 Sq. Ft. 304L Stainless Horizontal Heat Exchanger . 51" diameter X 26' face to face length. 304L Shell rated 110/FV @ -20 to 650 F. (1294) 304L tubes rated 110/FV @-20 to 550 F. Has 304L tubesheets and carbon steel heads. Fittings: (2) 16" inlet/outlet, (2) 1" Aux., (2) 1" vent/drain, (2) 18" inlet/outlet, (1) 2" Aux., (1) 1" vent, (1) 6" drain, (1) 2" Aux. NB# 15500, S/N 19-0072. Built 2019.
Stock No.:
53267103Used Rubicon 8500 Sq. Ft. 304L Tube Heat Exchanger – 51" x 26', Carbon Steel Shell
Used Rubicon 8500 Sq. Ft. 304L Tube Heat Exchanger 51" x 26', Carbon Steel Shell, rated 110/FV @ -20 to 650 F. (1294) 304L tubes rated 110/FV @-20 to 550 F. Has 304L tubesheets and carbon steel heads. Fittings: (2) 16" inlet/outlet, (2) 3/4" vent/drain, (1) 18" inlet, (1) 14" outlet, (4) 3/4" vent/drain, (2) 2" acid wash, and (1) 6" flush out. NB# 1959, S/N 3387-1A. Built 2007.
Stock No.:
53267117Used Southern Heat Exchanger Corp. 304L Stainless Steel Horizontal Heat Exchanger, Approximately 8500 sq. ft
Used- Southern Heat Exchanger Corp. 304L Stainless Steel Horizontal Heat Exchanger, Approximately 8500 sq. ft. 51" diameter X 26' face to face length. 304L Shell rated 110/FV @ -20 to 650 F. (1294) 304L tubes rated 110/FV @-20 to 550 F. Has 304L tubesheets and carbon steel heads. Fittings: (2) 16" inlet/outlet, (2) 1" Aux., (2) 1" vent/drain, (2) 18" inlet/outlet, (1) 2" Aux., (1) 1" vent, (1) 6" drain, (1) 2" Aux. NB# 15500. Built 2019.
Stock No.:
53267118Rubicon 8500 Sq. Ft. Shell & Tube Heat Exchanger – Carbon Steel Shell, 304L Tubes
Rubicon 8500 Sq. Ft. Shell & Tube Heat Exchanger Carbon Steel Shell, 304L Tubes. 51" diameter X 26' face to face length. Carbon Steel Shell rated 110/FV @ -20 to 650 F. (1294) 304L tubes rated 110/FV @-20 to 550 F. Has 304L tubesheets and carbon steel heads. Fittings: (2) 16" inlet/outlet, (2) 3/4" vent/drain, (1) 18" inlet, (1) 14" outlet, (4) 3/4" vent/drain, (2) 2" acid wash, and (1) 6" flush out. NB# 1959, S/N 3387-1A. Built 2007.
Stock No.:
53267119Used Rubicon 304L Tube Heat Exchanger – 51" Diameter, 26' Length, Built 2007
Used Rubicon 304L Tube Heat Exchanger 51" Diameter, 26' Length, Built 2007. Approximately 8500 sq. ft. Carbon Steel Shell rated 110/FV @ -20 to 650 F. (1294) 304L tubes rated 110/FV @-20 to 550 F. Has 304L tubesheets and carbon steel heads. Fittings: (2) 16" inlet/outlet, (2) 3/4" vent/drain, (1) 18" inlet, (1) 14" outlet, (4) 3/4" vent/drain, (2) 2" acid wash, and (1) 6" flush out. NB# 1959, S/N 3387-1A.
Stock No.:
53267120Rubicon Horizontal Heat Exchanger – 8500 Sq. Ft., Stainless Tubes, Heavy-Duty Use
Rubicon Horizontal Heat Exchanger 8500 Sq. Ft., Stainless Tubes, Heavy-Duty Use. 51" diameter X 26' face to face length. Carbon Steel Shell rated 110/FV @ -20 to 650 F. (1294) 304L tubes rated 110/FV @-20 to 550 F. Has 304L tubesheets and carbon steel heads. Fittings: (2) 16" inlet/outlet, (2) 3/4" vent/drain, (1) 18" inlet, (1) 14" outlet, (4) 3/4" vent/drain, (2) 2" acid wash, and (1) 6" flush out. NB# 1959, S/N 3387-1A. Built 2007.
Stock No.:
10749145Used – Hughes Anderson 971 sq. ft. Vertical Shell & Tube Heat Exchanger – Carbon Steel Shell, 304 SS Tubes
Used Hughes Anderson 971 sq. ft. Vertical Shell & Tube Heat Exchanger Carbon Steel Shell, 304 SS Tubes. 304 stainless steel heads. 75psi @ 340 degrees F. 75psi @ 280 degrees F tubes. 1" diameter tubes. 10'0" tube length. 391 tube holes. 1.25" tri tube pitch. 16 bwg tube wall. 1 pass shell. 1 pass tubes. NB code. Bel tema type. 3"and 6" shell nozzles. 6" and 16" tube nozzles. 3 baffles. 2'5" baffle spacing. 2'4" shell diameter. 14'2" overall length. With expansion joint.
MFR: Hughes Anderson
Stock No.:
10749144Used – Perry Products Shell & Tube Heat Exchanger – 984 sq. ft., Carbon Steel Shell & 316L SS Tubes
Used- Perry Products Shell and Tube Heat Exchanger. 984 sq foot. Carbon steel shell. 316L stainless steel tubes. 316L stainless steel heads. 90 psi @ 300 degrees F shell. 90 psi @ 300 degrees F tubes. 1" tube diameter. 16'0" tube length. 235 tube holes; 18 bwg tube wall. NB code. (2) 3" shell nozzles; 3" and 6" tube nozzles; 1'10" shell diameter. Built 1999.
MFR: Perry Products
Stainless Steel Shell & Tube Heat Exchanger Applications & Typical Use Cases
Used stainless steel shell and tube heat exchangers are commonly used in processes requiring reliable and efficient heat transfer. Typical applications include:
Heating and cooling process fluids in chemical manufacturing
Pasteurization and thermal processing in food and beverage production
Condensing and evaporating duties in industrial systems
Pharmaceutical processing requiring sanitary conditions
Heat recovery and energy efficiency applications
These exchangers are ideal for handling corrosive fluids and maintaining product purity.
When to Choose a Stainless Steel Shell & Tube Heat Exchanger
Stainless steel shell and tube heat exchangers are best suited for applications involving corrosive materials, hygienic requirements, or high-pressure and high-temperature conditions. They are often selected over other heat exchanger types when durability, cleanability, and material compatibility are critical. These systems are widely used when long service life and resistance to fouling or contamination are important factors.
Used Stainless Steel Shell & Tube Heat Exchanger Buying Considerations
When evaluating a used stainless steel shell and tube heat exchanger, consider:
Material grade: Verify stainless steel type (e.g., 304, 316) for corrosion resistance and process compatibility
Heat transfer area: Determines efficiency and suitability for required thermal load
Pressure and temperature ratings: Ensure compliance with operating conditions
Tube bundle condition: Inspect for fouling, corrosion, or damage affecting performance
Configuration and orientation: Fixed tube sheet, U-tube, or floating head designs impact maintenance and cleaning
Why Buy Used Stainless Steel Shell & Tube Heat Exchangers
Purchasing a used stainless steel shell and tube heat exchanger can significantly reduce capital costs while maintaining reliable heat transfer performance. Many units are available for immediate delivery, helping facilities avoid long fabrication lead times. Used equipment also provides access to durable, high-quality exchangers suitable for demanding industrial and sanitary applications.
Sell Your Used Stainless Steel Shell & Tube Heat Exchangers
Aaron Equipment purchases surplus and used stainless steel shell and tube heat exchangers from a wide range of manufacturers and configurations. Whether you are upgrading systems, decommissioning equipment, or liquidating assets, our team can assist with buyouts or consignment opportunities.
A stainless steel shell and tube heat exchanger is a thermal transfer device that uses a bundle of tubes inside a shell to transfer heat between fluids. Stainless steel construction provides corrosion resistance and durability for demanding applications.
They are used for heating, cooling, condensing, and evaporating fluids in industries such as chemical processing, food and beverage production, pharmaceuticals, and energy systems.
Stainless steel offers excellent corrosion resistance, durability, and cleanability, making it ideal for sanitary or corrosive applications. It is commonly used when product purity and long service life are critical.
The cost depends on factors such as size, material grade, pressure rating, configuration, and condition. Larger units or specialized designs typically command higher prices.
Yes. Aaron Equipment purchases used stainless steel shell and tube heat exchangers across a variety of sizes and configurations. Submit your equipment details to request an evaluation.