Used Plate Heat Exchangers for Sale
Plate heat exchangers are compact thermal transfer systems designed to efficiently transfer heat between fluids using a series of thin, corrugated plates. These plates create channels that maximize surface area and promote turbulent flow, improving heat transfer efficiency compared to traditional designs. Used plate heat exchangers are widely utilized in food and beverage, pharmaceuticals, chemical processing, and HVAC systems where space efficiency and thermal performance are critical. Aaron Equipment offers used plate heat exchangers for sale in a range of plate sizes, materials, and configurations to support various heating and cooling applications.
Stock No.:
54660006Never-Used Alfa Laval TL15-BFG Gasketed Plate Heat Exchanger
Purchased new and never put into operation, this Alfa Laval Model TL15-BFG gasketed plate heat exchanger is a 2022 unit with 139 plates. 1622 square foot. The unit has a maximum allowable working pressure (MAWP) of 150 PSI at 150F and a minimum design metal temperature (MDMT) of -20F at 150 PSI. It is ASME and National Board stamped, was purchased new, and has never been placed into service. Year 2022. Possible applications include industrial heating, cooling, heat recovery, process temperature control, HVAC, chemical, food and beverage, pharmaceutical, utility, water treatment, and manufacturing processes using compatible liquid products or process fluids.
MFR: Alfa Laval
Stock No.:
546600072022 Alfa Laval TL15-BFG 139-Plate Gasketed Heat Exchanger
Offered in unused condition, this 2022 Alfa Laval TL15-BFG gasketed plate heat exchanger has 139 plates providing 1,622.1 square feet of transfer area. The unit has a maximum allowable working pressure (MAWP) of 150 PSI at 150F and a minimum design metal temperature (MDMT) of -20F at 150 PSI. It is ASME and National Board stamped, was purchased new, and has never been placed into service. Year 2022. Possible applications include industrial heating, cooling, heat recovery, process temperature control, HVAC, chemical, food and beverage, pharmaceutical, utility, water treatment, and manufacturing processes using compatible liquid products or process fluids.
MFR: Alfa Laval
Stock No.:
54660008Unused Alfa Laval TL15-BFG 1,622 Sq. Ft. Plate Heat Exchanger
This unused 2022 Alfa Laval Model TL15-BFG heat exchanger uses a gasketed plate design with 139 plates and 1,622.1 square feet of heat-transfer surface. The unit has a maximum allowable working pressure (MAWP) of 150 PSI at 150F and a minimum design metal temperature (MDMT) of -20F at 150 PSI. It is ASME and National Board stamped, was purchased new, and has never been placed into service. Year 2022. Possible applications include industrial heating, cooling, heat recovery, process temperature control, HVAC, chemical, food and beverage, pharmaceutical, utility, water treatment, and manufacturing processes using compatible liquid products or process fluids.
MFR: Alfa Laval
Stock No.:
54660009Alfa Laval TL15-BFG Gasketed Heat Exchanger – 139 Plates, 2022
Manufactured in 2022, this unused Alfa Laval TL15-BFG gasketed plate heat exchanger is configured with 139 plates at 0.4 mm thickness. 1622 square foot. The unit has a maximum allowable working pressure (MAWP) of 150 PSI at 150F and a minimum design metal temperature (MDMT) of -20F at 150 PSI. It is ASME and National Board stamped, was purchased new, and has never been placed into service. Year 2022. Possible applications include industrial heating, cooling, heat recovery, process temperature control, HVAC, chemical, food and beverage, pharmaceutical, utility, water treatment, and manufacturing processes using compatible liquid products or process fluids.
MFR: Alfa Laval
Stock No.:
546600102022 Alfa Laval TL15-BFG 1,622.1 Sq. Ft. Heat Exchanger
This Alfa Laval Model TL15-BFG is a 2022 unused plate heat exchanger with a gasketed 139-plate configuration and 1,622.1 square feet of heat-transfer area. The unit has a maximum allowable working pressure (MAWP) of 150 PSI at 150F and a minimum design metal temperature (MDMT) of -20F at 150 PSI. It is ASME and National Board stamped, was purchased new, and has never been placed into service. Year 2022. Possible applications include industrial heating, cooling, heat recovery, process temperature control, HVAC, chemical, food and beverage, pharmaceutical, utility, water treatment, and manufacturing processes using compatible liquid products or process fluids.
MFR: Alfa Laval
Stock No.:
54660011Unused Alfa Laval TL15-BFG ASME Plate Heat Exchanger
Unused since purchased new, this 2022 Alfa Laval TL15-BFG gasketed plate heat exchanger includes 139 plates and carries ASME and National Board stamps. 1622 square foot. The unit has a maximum allowable working pressure (MAWP) of 150 PSI at 150F and a minimum design metal temperature (MDMT) of -20F at 150 PSI. It is ASME and National Board stamped, was purchased new, and has never been placed into service. Year 2022. Possible applications include industrial heating, cooling, heat recovery, process temperature control, HVAC, chemical, food and beverage, pharmaceutical, utility, water treatment, and manufacturing processes using compatible liquid products or process fluids.
MFR: Alfa Laval
Stock No.:
54660012Alfa Laval TL15-BFG 139-Plate Gasketed Heat Exchanger – Unused
Designed for gasketed plate heat-transfer service, this unused 2022 Alfa Laval Model TL15-BFG contains 139 plates with a thickness of 0.4 mm. 1,622.1 square feet of heat-transfer area. The unit has a maximum allowable working pressure (MAWP) of 150 PSI at 150F and a minimum design metal temperature (MDMT) of -20F at 150 PSI. It is ASME and National Board stamped, was purchased new, and has never been placed into service. Year 2022. Possible applications include industrial heating, cooling, heat recovery, process temperature control, HVAC, chemical, food and beverage, pharmaceutical, utility, water treatment, and manufacturing processes using compatible liquid products or process fluids.
MFR: Alfa Laval
Stock No.:
54660013Unused Alfa Laval TL15-BFG Plate Heat Exchanger – 1,622.1 Sq. Ft.
Featuring 1,622.1 square feet of heat-transfer area, this unused Alfa Laval TL15-BFG gasketed plate heat exchanger was purchased new and never commissioned. The unit has a maximum allowable working pressure (MAWP) of 150 PSI at 150F and a minimum design metal temperature (MDMT) of -20F at 150 PSI. It is ASME and National Board stamped, was purchased new, and has never been placed into service. Year 2022. Possible applications include industrial heating, cooling, heat recovery, process temperature control, HVAC, chemical, food and beverage, pharmaceutical, utility, water treatment, and manufacturing processes using compatible liquid products or process fluids.
MFR: Alfa Laval
Stock No.:
546600142022 Alfa Laval TL15-BFG Gasketed Plate Heat Exchanger – Unused
Available as an unused 2022 unit, this Alfa Laval Model TL15-BFG gasketed plate heat exchanger has 139 plates and a rated heat-transfer area of 1,622.1 square feet. The unit has a maximum allowable working pressure (MAWP) of 150 PSI at 150F and a minimum design metal temperature (MDMT) of -20F at 150 PSI. It is ASME and National Board stamped, was purchased new, and has never been placed into service. Year 2022. Possible applications include industrial heating, cooling, heat recovery, process temperature control, HVAC, chemical, food and beverage, pharmaceutical, utility, water treatment, and manufacturing processes using compatible liquid products or process fluids.
MFR: Alfa Laval
Stock No.:
54100001GEA Ecoflex VT10 Plate Heat Exchanger For Sale – 145 PSI, 212°F Rated – Approx.
Used- GEA Ecoflex GmbH Plate Heat Exchanger, Model VT10 CDS-17. Approximately 40 square foot area. Approximate (44) Stainless steel plates 31" x 8-1/2" wide. Operating pressure 0 to 145 psi (0 to 10 bar). Operating temperature 32 to 212 degrees F (0 to 100 degrees C). 2" Inlet/outlets. Mounted in an expandable frame. Serial# 169/16856.
Stock No.:
54112001Used Thermaline T13 Plate Heat Exchanger – Stainless Steel, 975,672 BTU/Hr
Used- Thermaline Plate Heat Exchanger, Model T13, Stainless Steel. Approximately 42.9 square feet. Flow rate: 44 GPM (Process Side), 145 GPM (Service process). Heat exchanged 975,672 BTU/Hr. Designed temperature 150 psi at 300 degrees F. Gasket material EPDM, CLIP. (33) Plate material 0.6mm, 316 Stainless Steel, CDX. Frame material 304 stainless steel. Serial# 27423-21.
Stock No.:
54112002Stainless Steel Thermaline Plate Heat Exchanger, 44/145 GPM – Used T13 Model
Pre-Owned Thermaline Plate Heat Exchanger, Model T13, Stainless Steel. Approximately 42.9 square feet. Flow rate: 44 GPM (Process Side), 145 GPM (Service process). Heat exchanged 975,672 BTU/Hr. Designed temperature 150 psi at 300 degrees F. Gasket material EPDM, CLIP. (33) Plate material 0.6mm, 316 Stainless Steel, CDX. Frame material 304 stainless steel. Serial# 27423-22.
Plate Heat Exchanger Applications & Typical Use Cases
Used plate heat exchangers are commonly used in applications requiring efficient and compact heat transfer. Typical use cases include:
Heating and cooling process fluids in chemical manufacturing
Pasteurization and temperature control in food and beverage production
HVAC and building cooling systems
Pharmaceutical and sanitary processing applications
Heat recovery and energy efficiency systems
These exchangers are ideal for processes requiring precise temperature control and high efficiency.
When to Choose a Plate Heat Exchanger
Plate heat exchangers are best suited for applications requiring high heat transfer efficiency in a compact footprint. They are typically selected when space constraints or energy efficiency are priorities. Compared to shell and tube heat exchangers, plate designs offer greater thermal efficiency and easier maintenance, making them ideal for sanitary and frequently serviced applications.
Used Plate Heat Exchanger Buying Considerations
When evaluating a used plate heat exchanger, consider:
Plate material and gasket type: Ensure compatibility with process fluids and operating conditions
Heat transfer area: Determines capacity and thermal performance
Pressure and temperature ratings: Verify suitability for process requirements
Plate condition and fouling: Inspect for wear, scaling, or damage
Frame and tightening system: Ensure structural integrity and proper sealing
Why Buy Used Plate Heat Exchangers
Purchasing a used plate heat exchanger can significantly reduce capital costs while maintaining efficient heat transfer performance. Many units are available for immediate delivery, helping facilities avoid long lead times associated with new equipment. Used exchangers also provide access to compact, high-efficiency systems suitable for a wide range of industrial applications.
Sell Your Used Plate Heat Exchangers
Aaron Equipment purchases surplus and used plate heat exchangers from a wide range of manufacturers and configurations. Whether you are upgrading systems, decommissioning equipment, or selling idle assets, our team can assist with buyouts or consignment opportunities.
A plate heat exchanger is a thermal transfer device that uses multiple thin plates to transfer heat between fluids. The plate design increases surface area and improves efficiency compared to traditional heat exchangers.
Plate heat exchangers are used for heating, cooling, pasteurization, and heat recovery in industries such as food processing, pharmaceuticals, chemical manufacturing, and HVAC systems.
Plate heat exchangers are more compact and offer higher heat transfer efficiency, while shell and tube exchangers are typically used for higher pressure or temperature applications. Plate systems are often easier to clean and maintain.
The cost of a used plate heat exchanger depends on size, material, pressure rating, manufacturer, and condition. Larger or specialized units typically command higher prices.
Yes. Aaron Equipment purchases used plate heat exchangers across a range of sizes and configurations. If you have equipment available for sale, submit your details to receive an evaluation.