Used Waukesha 4000kW natural gas power plant consisting of (5) Waukesha generator sets as follows: Unit #1 Waukesha model L5108GL SN-C-93726/4, 770 kWe continuous 3/60/4160V, total hours 30,420. Major overhaul at 28,565 hours September 2009, built 1996. Unit #2 Waukesha model L5108GL SN-C-93726/2, 770 kWe continuous 3/60/4160V, total hours 31,963. Minor overhaul at 16,688 hours April 2003. Built 1996. Unit #3 Waukesha original model L5108GL SN- C-93726/3. Short blocked with a L7042GL. 975-303. 770 kWe continuous 3/60/4160V, total hours 24,997, short blocked at 22,299 hours April 2008. Built 1996. Unit #4 Waukesha L5108GL SN-C-93726/1 770 kWe continuous 3/60/4160V. Total hours 24,937. Minor overhaul at 23,457 hours August 2010, built 1996. Unit #5 Waukesha L7042GSI SN- C-94523/1, 900 kWe continuous 3/60/4160V. Total hours 13,458. Turbochargers replaced. Unit has valve recession recommend minor overhaul due. Built 2003.Includes paralleling switchgear, controls, breakers and cabinets. Note: We are only offering the engine / genset skids and paralleling switchgear, controls, breakers and cabinets, no mufflers, no radiators, no Co-gen related equipment. Previously used in a CHP / Co-Gen plant from a College that was peak shaving and providing supplemental heating & cooling.
Used Waukesha 4000kW natural gas power plant consisting of (5) Waukesha generator sets as follows: Unit #1 Waukesha model L5108GL SN-C-93726/4, 770 kWe continuous 3/60/4160V, total hours 30,420. Major overhaul at 28,565 hours September 2009, built 1996. Unit #2 Waukesha model L5108GL SN-C-93726/2, 770 kWe continuous 3/60/4160V, total hours 31,963. Minor overhaul at 16,688 hours April 2003. Built 1996. Unit #3 Waukesha original model L5108GL SN- C-93726/3. Short blocked with a L7042GL. 975-303. 770 kWe continuous 3/60/4160V, total hours 24,997, short blocked at 22,299 hours April 2008. Built 1996. Unit #4 Waukesha L5108GL SN-C-93726/1 770 kWe continuous 3/60/4160V. Total hours 24,937. Minor overhaul at 23,457 hours August 2010, built 1996. Unit #5 Waukesha L7042GSI SN- C-94523/1, 900 kWe continuous 3/60/4160V. Total hours 13,458. Turbochargers replaced. Unit has valve recession recommend minor overhaul due. Built 2003.Includes paralleling switchgear, controls, breakers and cabinets. Note: We are only offering the engine / genset skids and paralleling switchgear, controls, breakers and cabinets, no mufflers, no radiators, no Co-gen related equipment. Previously used in a CHP / Co-Gen plant from a College that was peak shaving and providing supplemental heating & cooling.
We pay "Top Dollar" for your idle process equipment! Fill out our form and our buying team will get back to you.
SELL YOUR EQUIPMENTView our entire process equipment inventory online or visit our location for an equipment inspection.
View Inventory