Used Diesel Fuel Generators & Natural Gas Fuel Generators

Browse Aaron Equipment's inventory of low hour used diesel generators and natural gas gen sets. Aaron Equipment stocks dependable, ready-to-ship diesel generators ranging in size from 100kW to 2000kW. Our entire inventory of unused and used diesel and natural gas generators in our inventory is available for a load test prior to sale. Diesel generators are devices that use a diesel engine to produce electricity. They are widely used as primary or backup power sources in various applications, including residential, commercial, and industrial settings. If you are looking to sell your used diesel generator submit a request online or contact Erik Eichert at 630-238-7480.

36 Diesel Fuel & Natural Gas Fuel Generators

Enter to Search

Used Caterpillar C280-8 Offshore Diesel Generator Set – 2200 kW, Kato Generator, 900 RPM

Used Caterpillar C280-8 Offshore Diesel Generator Set – 2200 kW, Kato Generator, 900 RPM

Stock# 52504003

Used Caterpillar 2,200kW Offshore Diesel Generator Set, Model C280-8. Diesel Engine Model 3608, I-8 4-Stroke-Cycle-Diesel. Rated Speed: 900 RPM; Kato Engineering Generator; Model AA28661000; Potency: 3.142,9 Kwa / 2.200 Kw, 3 phase, 60Hz, 346/600 Volts, 3.024 Ah.

KW: 2,200 Mfr: Caterpillar Fuel: Diesel Volts: 346/600
VIEW ITEM ADD TO CART

Cummins 2000 kW Diesel Generator, Model QSK60-G6

Cummins 2000 kW Diesel Generator, Model QSK60-G6

Stock# 53746001

Used Cummins 2000 kW Diesel Generator, Model QSK60-G6. Completely overhauled in 2024. Originally built in 2008. Services performed: Cleaning and honing of the pistons (the pistons are still in standard diameter, with no wear); Replacement of all cylinder liners and liner rings (still in standard diameter, with no wear); Comprehensive machining of all cylinder heads; Replacement of all cylinder head valves; Replacement of main and connecting rod bearings; Cleaning and honing of the crankshaft; Removal and maintenance of the injection actuators; Removal and maintenance of all injectors; Removal of the radiators, complete repairs and testing; Removal and maintenance of the intercoolers; Removal and inspection of the turbochargers (4 units); Inspection and maintenance of the water pump; Cleaning of the water pipes and galleries; Replacement of all fluids and filters;Complete inspection of the electrical wiring harness; Alternator (Stanford Generator) Rewinding of the alternator rotor; Rewinding of the alternator stator; Inspection and maintenance of Cummins GDRIVE control module; Inspection and maintenance of Control panel; The genset controller is new: COMAP IG4 200 - on-grid and off-grid operation. The genset was completely tested after the services.

KW: 2,000 Mfr: Cummins Fuel: Diesel Volts:
VIEW ITEM ADD TO CART

Used Cummins QSV91G 1540 KW Natural Gas Generator

Used Cummins QSV91G 1540 KW Natural Gas Generator

Stock# 53868001

Used Cummins Generator Set, Model QSV91G. Rated 1540kW; 480 Volt, 91-liter natural gas engine with a low BTU system mounted on it; Has cooler, breakers, and controllers. Engine suitable for both pipeline and landfill gas. Serial# F15K840326. Built 2015. Unit has 60 test hours.

KW: 1,540 Mfr: Cummins Fuel: Natural Gas Volts: 480
VIEW ITEM ADD TO CART

Used Cummins Model DFLC.1250 kW Standby (1100 kW prime) Diesel Generator Set

Used Cummins Model DFLC.1250 kW Standby (1100 kW prime) Diesel Generator Set

Stock# 49317026

Cummins 1250 kW standby (1100 kW prime) diesel generator set model DFLC, SN-E990917734. Cummins KTA50-G3 engine rated 1850 HP at 1800 RPM, SN-33143120. 3/60/277/480V. 1600 Amp main-line circuit breaker. PMG - permanent magnet generator. PowerCommand digital control panel. Dual coolant heaters. Open power unit with engine driven radiator. Overall dimensions 90W x 222L x 97H, 25,160 lbs. 400 Hrs. Yr 1999. Passed load test 9/3/2024. FOB Waukesha, WI

KW: 1,250 Mfr: Cummins Fuel: Diesel Volts: 480
VIEW ITEM ADD TO CART

Master 1100kW Standby Twin Pack Volvo Tier 4 Final Diesel Generator,

Master 1100kW Standby Twin Pack Volvo Tier 4 Final Diesel Generator,

Stock# 40958016

Unused- Master 1100kW Standby Twin Pack Volvo Tier 4 Final Diesel Generator, Model MP-V1100TP. 1100kW Twin Pack; Volvo TWD1672GE; Stamford S6L1D-G; SmartGen control panel: HGM; Smart Gen Controller HGH; 40' GP Soundproof/Weatherproof Containerized Enclosure with corrosion proofing package; High performance circuit breaker; Hardwire terminals; Chassis; Tier 4 Final; 8 hour base fuel tank; inbuilt 1600 Amp automatic transfer switch; 40' GP soundproof/weatherproof containerized enclosure chassis; Built-in ATS 1600AMP; 3/480V. Built 2024. With warranty.

KW: 1,100 Mfr: Master Fuel: Diesel Volts:
VIEW ITEM ADD TO CART

Used MTU 1000 kW Standby Diesel Gen Set

Used MTU 1000 kW Standby Diesel Gen Set

Stock# 49317030

Used MTU 1000 kW Standby Diesel Generator Set. MTU 16V2000 engine rated 1495 HP at 1800 RPM, SN-5362000574. 3/60/277/480V. main-line circuit breaker. Generator end has 180 hrs. Battery charger. Coolant heater. Open power unit. 17,596 Hrs. Year 1999.

KW: 1,000 Mfr: MTU Onsite Energy Fuel: Diesel Volts: 480
VIEW ITEM ADD TO CART

Used 1000 kW Cummins QST30-G5 Diesel Generator – Tier 2

Used 1000 kW Cummins QST30-G5 Diesel Generator – Tier 2

Stock# 53259002

Used 1000 kW Cummins QST30-G5 Diesel Generator. EPA Tier 2. Sound-attenuated enclosure. Busbar M12. 2500 Amp Merlin Gerin Masterpact NW25 Micrologic 5.0 breaker. 340.3 gallon diesel base tank. 20 foot ISO container. 3phase/60hertz/277/480volt. 342 hours. 1505 Amps.1800 RPM. Year 2011.

KW: 1,000 Mfr: Cummins Fuel: Diesel Volts: 480
VIEW ITEM ADD TO CART

Used Cummins QST30-G5 1000kW Diesel Generator – Tier 2, Industrial Power

Used Cummins QST30-G5 1000kW Diesel Generator – Tier 2, Industrial Power

Stock# 53259003

Used Cummins 1000 kW Model QST30-G5 Diesel Generator. EPA Tier 2. Sound-attenuated enclosure. Busbar M12. 2500 Amp Merlin Gerin Masterpact NW25 Micrologic 5.0 breaker. 340.3 gallon diesel base tank. 20 foot ISO container. 3phase / 60hertz / 277/480 volt. 1505 Amps. 1800 RPM. Year 2011. 370 Hours.

KW: 1,000 Mfr: Cummins Fuel: Diesel Volts: 277/480
VIEW ITEM ADD TO CART

Used 3.2 MW Cogeneration Plant – (4) Caterpillar G3516 Engines, Trane Chillers, Heat Recovery

Used 3.2 MW Cogeneration Plant – (4) Caterpillar G3516 Engines, Trane Chillers, Heat Recovery

Stock# 51543001

Used 3.2 MW Cogeneration Plant;Includes: (4) Caterpillar G3516 SITA engines, mated to Caterpillar SR-4 or SR-4B generators rated at 800KW; 480V, 1200A. The plant is designed to run on Natural Gas with (2) 420 Ton Trane Absorption Chillers; (1) 630 Ton Trane Centrifugal Chiller, and (1) Recold chiller unit; All energy is recovered through a system of exhaust and cooling water heat recovery units. The units have wet exhaust systems that capture the exhaust heat, as well as the cooling water heat in a shell and tube heat exchanger (one for each generator). Exhaust gas temperature is approximately 800F, and block water enters the heat exchanger at 205F. After the heat exchanger, water enters the two absorption chillers at 230F. Engine intake water is approximately 200F after processing through the chillers. The (2) generator turbos are cooled through a closed cooling loop with a Recold unit. Mfg. 2009.

KW: 800 Mfr: Caterpillar Fuel: natural Volts: 480
VIEW ITEM ADD TO CART

Used MTU 600 kW Standby (550 kW prime) Diesel Generator Set - Model DS600

Used MTU 600 kW Standby (550 kW prime) Diesel Generator Set - Model DS600

Stock# 49317033

Used MTU 600 kW Standby (550 kW prime) Diesel Generator Set, Model DS600, SN-321178-1-1-0510. MTU 12V1600G80S engine rated 896 HP at 1800 RPM, SN-16701001344, EPA Tier 2 emissions. 3/60/120/208V, 12 lead reconnectable to other voltages. 2000 Amp adjustable main-line circuit breaker. PMG permanent magnet generator. Engine cooling radiator rated 50C/122F ambient. UL listed stationary engine generator assembly. Basler DGC-2020 digital control panel. Battery charger. Coolant heater. Weather enclosure. 1000 gallon sub-base fuel tank with secondary containment. 293 Hrs. Year 2010. 86W x 170L x 144H, 20,000 lbs. Passed load test 6/11/2024.

KW: 600 Mfr: MTU Onsite Energy Fuel: Diesel Volts: 208
VIEW ITEM ADD TO CART

Used Caterpillar 600 kW Standby Diesel Generator Set – CAT 3412, 896 HP, 1159 Hrs

Used Caterpillar 600 kW Standby Diesel Generator Set – CAT 3412, 896 HP, 1159 Hrs

Stock# 49317037

Used Caterpillar 600 kW Standby (545 kW prime) Diesel Generator Set. CAT 3412 engine rated 896 HP at 1800 RPM, SN-81Z19106. 3/60/277/480V, 12 lead reconnectable to other voltages. 1000 Amp main-line circuit breaker. EMCP II digital control panel. Battery charger. Coolant heater. Sound attenuated enclosure. 3400 gallon sub-base fuel tank with secondary containment. 1159 Hrs. Built 1996. Overall dimensions 114W x 313L x 160H 38,000 lbs. Passed load test 11/20/2024.

KW: 600 Mfr: Caterpillar Fuel: Diesel Volts: 277/480
VIEW ITEM ADD TO CART

Used Hi-Power 500 kW Standby Generator – Perkins Engine, Low Hours, Load Bank Tested

Used Hi-Power 500 kW Standby Generator – Perkins Engine, Low Hours, Load Bank Tested

Stock# 53050004

Used Hi-Power 500 kW Standby Unit. Perkins Engine rated 432.5 bkW. Sound Attenuated. 920 gallon base fuel tank. 3/60/480. 1800 RPM. 705 hours. Load Banked Tested! Passed with No Issues. Trailer can be purchased with unit for additional cost.

KW: 500 Mfr: Hi-Power Fuel: Diesel Volts: 480
VIEW ITEM ADD TO CART

Unused Caterpillar 455 kW Standby Generator Set – CAT C18 Engine

Unused Caterpillar 455 kW Standby Generator Set – CAT C18 Engine

Stock# 40958023

Unused- Caterpillar 455 kW Standby Generator Set. CAT C18 Engine. 1800 RPM. Control Panel. Open skid unit. 3/60/480 Volt.

KW: 455 Mfr: Caterpillar Fuel: Volts:
VIEW ITEM ADD TO CART

Caterpillar Model C18 455kW Industrial Generator

Caterpillar Model C18 455kW Industrial Generator

Stock# 40958024

Unused- CAT 455Kw generator, Model 455. CAT Engine, model C18, Open skid unit.

KW: 455 Mfr: Caterpillar Fuel: Volts:
VIEW ITEM ADD TO CART

Unused Caterpillar 455 kW Standby Industrial Generator Set with CAT C18 Engine

Unused Caterpillar 455 kW Standby Industrial Generator Set with CAT C18 Engine

Stock# 40958025

Unused- Caterpillar 455 kW Standby Industrial Generator Set. CAT C18 Engine. 1800 RPM. Control Panel. Open skid unit. 3/60/480 Volt.

KW: 455 Mfr: Caterpillar Fuel: Volts:
VIEW ITEM ADD TO CART

Used CAT Model C15 Engine 400kW Diesel Generator | Ready To Ship

Used CAT Model C15 Engine 400kW Diesel Generator | Ready To Ship

Stock# 53758001

Used Caterpillar 400 kW (365 kW prime) Standby Diesel Generator Set, SN-C5E03099. CAT C15 engine rated 619 HP at 1800 RPM, SN-FSE03694, EPA Tier 3 emissions. 3/60/277/480V, 12 lead reconnectable to other voltages. 800 Amp main-line circuit breaker. PMG - Permanent magnet generator. EMCP 3.2 digital control panel. UL listed package. Sens battery charger. Coolant heater. Weather enclosure. 400 gallon sub-base fuel tank with secondary containment. 429 Hrs. Year 2011. CAT Worldwide ESC warranty 1-5 years available at additional cost. Passed load test 1/24/2025.

KW: 400 Mfr: Caterpillar Fuel: Diesel Volts: 277/480
VIEW ITEM ADD TO CART

Triton 350 kW Used Triton 350 kW Diesel Generator – Volvo Engine, Trailer-Mounted, Low Hours

Triton 350 kW Used Triton 350 kW Diesel Generator – Volvo Engine, Trailer-Mounted, Low Hours

Stock# 53050006

Used Triton 350 kW Generator. Volvo Engine. Weather-proof enclosure. 1000 Gallon DW Base Fuel Tank; Magna Plus Gen Head; Block Heater; Auto Start SDMO Control Panel. Display screen has faded. New tires on trailer. 3/60/480. 1800 RPM. Approx. 1000 hours. Can be sold without trailer for discounted price.

KW: 350 Mfr: Triton Fuel: Diesel Volts: 480
VIEW ITEM ADD TO CART

Generac Natural Gas Generator, Model MG0300

Generac Natural Gas Generator, Model MG0300

Stock# 53657001

Used Generac Natural Gas Generator, Model MG0300. 300 KW. Enclosed OH0924 Engine. Built 2012. 3/60/277/480V. 160 hours. Serial# 2114542.

KW: 300 Mfr: Generac Fuel: Natural Gas Volts: 480
VIEW ITEM ADD TO CART

Unused Cummins 300 kW Natural Gas Standby Generator Set – Model C300N6

Unused Cummins 300 kW Natural Gas Standby Generator Set – Model C300N6

Stock# 49317038

Unused- Natural Gas, Cummins 300 kW Standby Generator Set, Model C300N6. Cummins GTA GTA855EICS 14L engine rated 470 HP at 1800 RPM. EPA certified. 3/60/277/480V, 12 lead reconnectable to other voltages. 600 Amp 100% rated main-line circuit breaker. PMG permanent magnet generator. UL 2200 listed package. Cummins Power Command 3.3 MLD utility-rated paralleling digital control panel. Sens battery charger 12 amp 120/208/240V. Coolant heater 2500W. Catalyst, 5 in flange, NSPS 2/4/1. Level 2 sound attenuated aluminum enclosure 100 MPH wind rating. 0 Hours. Built 2024. Cummins 2 Yr 1000 Hr limited warranty. Overall dimensions 70W x 281L x 97H on 6H blocks, 10,970 lbs.

KW: 300 Mfr: Cummins Fuel: Natural Gas Volts: 480
VIEW ITEM ADD TO CART

Used Multiquip 250/275 kW Diesel Generator – Iveco Engine, Low Hours, Weatherproof

Used Multiquip 250/275 kW Diesel Generator – Iveco Engine, Low Hours, Weatherproof

Stock# 53050005

Used Multiquip 250/275kW Generator. Iveco Engine. WP Enclosure; 1600 DW Base Fuel Tank; Magna Plus Gen Head; Main Breaker; Block Heater; Auto Start Control Panel. 3/60/480. 1800 RPM. 750 Hours.

KW: 250 Mfr: Multiquip Fuel: Diesel Volts: 480
VIEW ITEM ADD TO CART

Cummins Standby Natural Gas Generator, Model 235GFBC

Cummins Standby Natural Gas Generator, Model 235GFBC

Stock# 53555002

Used Cummins Standby Natural Gas Generator, Model 235GFBC. Rated 235 kW. With enclosure. Cummins model GTA855G3 engine Serial# 25303054, Approximately 354hp. 3/60/480V, 1800 RPM. Built 2005. 920 hours.

KW: 235 Mfr: Cummins Fuel: Natural Gas Volts: 480
VIEW ITEM ADD TO CART

Cummins Model GGLB 150 kW Standby Natural Gas / Propane Generator

Cummins Model GGLB 150 kW Standby Natural Gas / Propane Generator

Stock# 53670001

Used Cummins 150 kW Standby Natural Gas / Propane Generator Set, Model GGLB, SN-D060916175. GM 8.1L engine rated 225 HP at 1800 RPM, 3/60/277/480V. 400 Amp main-line circuit breaker. PMG - permanent magnet generator. UL 2200 listed package. Oversized generator end rated 180 kW. PowerCommand 2100 digital control panel. Coolant heater. Sound attenuated enclosure. 1159 Hrs. Built 2006.

KW: 150 Mfr: Cummins Fuel: Natural Gas Volts: 277/480
VIEW ITEM ADD TO CART

Cummins Model DSHAA 150kW Standby Diesel Generator

Cummins Model DSHAA 150kW Standby Diesel Generator

Stock# 53670002

Used Cummins 150 kW Standby (135 kW prime) Diesel Generator, Model DSHAA, SN-D060916181. Cummins QSL9-G2 engine rated 364 HP at 1800 RPM, SN-46580071, EPA Tier 3 emissions. 225 Amp main-line circuit breaker. 3/60/277/480V, 12 lead reconnectable to other voltages. Oversized generator end rated 180 kW. PowerCommand 2100 digital control panel. UL 2200 listed stationary engine-generator assembly. Sound attenuated enclosure. 366 gallon UL listed sub-base fuel tank w/secondary containment. 610 Hrs. Year 2006.

KW: 150 Mfr: Cummins Fuel: Diesel Volts: 277/480
VIEW ITEM ADD TO CART

Used SDMO/John Deere 155 kVA Diesel Generator – Trailerized, Prime Power, Low Hours

Used SDMO/John Deere 155 kVA Diesel Generator – Trailerized, Prime Power, Low Hours

Stock# 53050001

Used SDMO/John Deere Diesel Rental Grade Trailerized Unit. 155Kva/128Kw. Set for Continuous Prime Power. Selector Switch for Multi Voltages; Sound Attenuated Enclosure; Main Breaker on Deck; Gang Box on Rear for Storage of Cables; Tandem Axle Trailer; (2) Spare Tires on Deck; Cam Loc Cables on Deck; Auto Start or Manual Start; Lock Key Box on Deck; Block Heater; Battery Charger. Built 2007. 1142 Hours. Batteries may be dead.

KW: 128 Mfr: SDMO Fuel: Diesel Volts:
VIEW ITEM ADD TO CART

Used John Deere / SDMO 155 kVA Diesel Generator – Portable - Prime Power -Low Hours

Used John Deere / SDMO 155 kVA Diesel Generator – Portable - Prime Power -Low Hours

Stock# 53050003

Used John Deere / SDMO Diesel Rental Grade Trailerized Unit, 155Kva/128Kw. Set for Continuous Prime Power. Selector Switch for Multi Voltages; Sound Attenuated Enclosure; Main Breaker on Deck; Gang Box on Rear for Storage of Cables; Tandem Axle Trailer; (2) Spare Tires on Deck; Cam Loc Cables on Deck; Auto Start or Manual Start; Lock Key Box on Deck; Block Heater; Battery Charger. 873 Hours. Batteries may be dead.

KW: 128 Mfr: SDMO Fuel: Diesel Volts:
VIEW ITEM ADD TO CART

Kohler Standby Natural Gas Generator, Model 125REZGC.

Kohler Standby Natural Gas Generator, Model 125REZGC.

Stock# 53555001

Used Kohler Standby Natural Gas Generator, Model 125REZGC. Rated 125 kW. With enclosure. 1800 RPM. 3/60/277/480V. Built 2013. 2167 hours.

KW: 125 Mfr: Kohler Fuel: Natural Gas Volts: 480
VIEW ITEM ADD TO CART

Olympian Model D100P1 Mobile Diesel Generator, 100kW

Olympian Model D100P1 Mobile Diesel Generator, 100kW

Stock# 53744001

Used Portable / Trailerized Olympian Diesel Generator, Model D100P1. Rated 100 kW. 1800RPM, 166 HP, 3/60/120/208V Perkins Engine. Built 2001. 70 hours. All fluids recently changed and load tested.

KW: 100 Mfr: Olympian Fuel: Diesel Volts: 208
VIEW ITEM ADD TO CART

Olympian 75kW Standby Natural Gas Generator Set

Olympian 75kW Standby Natural Gas Generator Set

Stock# 53337005

Used Olympian 75kW Standby Natural Gas Generator Set, Model G80F3. Ford engine model WSG1068I6005E-NA, approximate 112HP, 1800 RPM, SN-03-09-060446. Weather enclosure. 3/60/120/208 Volt. 577 hours. Serial# OLY00000JNFC01262, Built 2003.

KW: 75 Mfr: Ford Fuel: Natural Gas Volts: 120/208
VIEW ITEM ADD TO CART

Used Cummins 75 kW Standby Natural Gas / Propane Generator Set – Model GGHF

Used Cummins 75 kW Standby Natural Gas / Propane Generator Set – Model GGHF

Stock# 52997001

Used Cummins 75 kW Standby Natural Gas / Propane Generator Set, Model GGHF - 5756500, SN-C060905687. Ford WSG1068 6.8L engine rated 126 HP at 1800 RPM, SN-06YS53164. 1/60/120/240V single phase. 350 Amp main-line circuit breaker. UL listed package. PowerCommand digital control panel. EnerGenius battery charger. Coolant heater. Sound attenuated enclosure. 418 Hrs.

KW: 75 Mfr: Cummins Fuel: Natural Gas / Propane Volts: 120/240
VIEW ITEM ADD TO CART

Used Multiquip Diesel DCA-125SSJU Trailerized Generator – 72 kW, 3-Phase, 240/480V

Used Multiquip Diesel  DCA-125SSJU Trailerized Generator – 72 kW, 3-Phase, 240/480V

Stock# 53884003

Used Multiquip Trailerized Diesel Generator, Model DCA-125SSJU. Rated 72 kW; 3/60/240/480V; 150 HP, 1800 RPM John Deere 6068TF engine; 227 hours.

KW: 72 Mfr: Multiquip Fuel: Diesel Volts: 480
VIEW ITEM ADD TO CART

Used Trailerized Multiquip Model DCA-70SSIU2fDiesel Generator

Used Trailerized Multiquip Model DCA-70SSIU2fDiesel Generator

Stock# 53884002

Used Multiquip Trailerized Diesel Generator, Model DCA-70SSIU2. Rated 56 kW; 3/60/240/480V; 85 HP, 1800 RPM Isuzu 4JJ1x engine; 1774 hours.

KW: 56 Mfr: Multiquip Fuel: Diesel Volts: 480
VIEW ITEM ADD TO CART

2023 Cummins C50D6C Generator 50kW

2023 Cummins C50D6C Generator 50kW

Stock# 40958019

Unused- 2023 Cummins C50D6C Generator 50kW. Open skid 120/208 volt 3 phase 60 hz Diesel generator 50 Gallon Pryco Day Tank Generator breaker 70amp / 125amp / 175 amp 2 / ATS 125 AMP and 70 AMP Split loads Exhaust System with Particulate filter. 3

KW: 50 Mfr: Cummins Fuel: Diesel Volts: 208
VIEW ITEM ADD TO CART

Onan 35 kW Natural Gas Generator Set: Reliable Standby Power Solution

Onan 35 kW Natural Gas Generator Set: Reliable Standby Power Solution

Stock# 51825001

Used Cummins / Onan 35 kW Standby Natural Gas Generator Set, Model 35SJB, SN-L900363017. Chrysler model H135 engine, SN-K1142033, 3600rpm. Rated 35 kW, 3/60/277/480V 12 lead reconnectable to other voltages.. 60 Amp main-line circuit breaker. Hours 403. No enclosure.

KW: 35 Mfr: Cummins/Onan Fuel: natural gas Volts: 277/480
VIEW ITEM ADD TO CART

Used Multiquip DCA-25USI2 Trailerized Diesel Generator – 20 kW, 3-Phase, 240/480V

Used Multiquip DCA-25USI2 Trailerized Diesel Generator – 20 kW, 3-Phase, 240/480V

Stock# 53884001

Used Multiquip Trailerized Diesel Generator, Model DCA-25USI2. Rated 20 kW; 3/60/240/480V; 30.6 HP, 1800 RPM Isuzu 4LE2 engine; 74 hours.

KW: 20 Mfr: Multiquip Fuel: Diesel Volts: 480
VIEW ITEM ADD TO CART

Used Caterpillar C280-8 Offshore Diesel Generator Set – 2200 kW, Kato Generator, 900 RPM

Used Caterpillar C280-8 Offshore Diesel Generator Set – 2200 kW, Kato Generator, 900 RPM

Stock# 52504001

Used Caterpillar Offshore Generator Set, Model C280-8, Diesel Engine 3608, I-8 4-Stroke-Cycle-Diesel. Rated Speed: 900 RPM; Kato Engineering Generator; Model AA28661000; Potency: 3.142,9 Kwa / 2.200 Kw, 3 phase, 60Hz, 346/600 Volts, 3.024 Ah.

KW: Mfr: Caterpillar Fuel: Diesel Volts:
VIEW ITEM ADD TO CART

Caterpillar C280-8 Offshore Diesel Generator Set – 2200 kW, Kato Generator, 900 RPM

Caterpillar C280-8 Offshore Diesel Generator Set – 2200 kW, Kato Generator, 900 RPM

Stock# 52504002

Used Caterpillar Model C280-8 Offshore Generator Set. Diesel Engine Model 3608, I-8 4-Stroke-Cycle-Diesel. Rated Speed: 900 RPM; Kato Engineering Generator; Model AA28661000; Potency: 3.142,9 Kwa / 2.200 Kw, 3 phase, 60Hz, 346/600 Volts, 3.024 Ah.

KW: Mfr: Caterpillar Fuel: Diesel Volts:
VIEW ITEM ADD TO CART
  • Used Caterpillar C280-8 Offshore Diesel Generator Set – 2200 kW, Kato Generator, 900 RPM

    Used Caterpillar 2,200kW Offshore Diesel Generator Set, Model C280-8. Diesel Engine Model 3608, I-8 4-Stroke-Cycle-Diesel. Rated Speed: 900 RPM; Kato Engineering Generator; Model AA28661000; Potency: 3.142,9 Kwa / 2.200 Kw, 3 phase, 60Hz, 346/600 Volts, 3.024 Ah.

    VIEW ITEM
  • Cummins 2000 kW Diesel Generator, Model QSK60-G6

    Used- Cummins 2000 kW Diesel Generator, Model QSK60-G6. Completely overhauled in 2024. Originally built in 2008. Services performed: Cleaning and honing of the pistons (the pistons are still in standard diameter, with no wear); Replacement of all cylinder liners and liner rings (still in standard diameter, with no wear); Comprehensive machining of all cylinder heads; Replacement of all cylinder head valves; Replacement of main and connecting rod bearings; Cleaning and honing of the crankshaft; Removal and maintenance of the injection actuators; Removal and maintenance of all injectors; Removal of the radiators, complete repairs and testing; Removal and maintenance of the intercoolers; Removal and inspection of the turbochargers (4 units); Inspection and maintenance of the water pump; Cleaning of the water pipes and galleries; Replacement of all fluids and filters;Complete inspection of the electrical wiring harness; Alternator (Stanford Generator) Rewinding of the alternator rotor; Rewinding of the alternator stator; Inspection and maintenance of Cummins GDRIVE control module; Inspection and maintenance of Control panel; The genset controller is new: COMAP IG4 200 - on-grid and off-grid operation. The genset was completely tested after the services.

    VIEW ITEM
  • Used Cummins QSV91G 1540 KW Natural Gas Generator

    Used- Cummins Generator Set, Model QSV91G. Rated 1540kW; 480 Volt, 91-liter natural gas engine with a low BTU system mounted on it; Has cooler, breakers, and controllers. Engine suitable for both pipeline and landfill gas. Serial# F15K840326. Built 2015. Unit has 60 test hours.

    VIEW ITEM
  • Used Cummins Model DFLC.1250 kW Standby (1100 kW prime) Diesel Generator Set

    Cummins 1250 kW standby (1100 kW prime) diesel generator set model DFLC, SN-E990917734. Cummins KTA50-G3 engine rated 1850 HP at 1800 RPM, SN-33143120. 3/60/277/480V. 1600 Amp main-line circuit breaker. PMG - permanent magnet generator. PowerCommand digital control panel. Dual coolant heaters. Open power unit with engine driven radiator. Overall dimensions 90W x 222L x 97H, 25,160 lbs. 400 Hrs. Yr 1999. Passed load test 9/3/2024. FOB Waukesha, WI

    VIEW ITEM
  • Master 1100kW Standby Twin Pack Volvo Tier 4 Final Diesel Generator,

    Unused- Master 1100kW Standby Twin Pack Volvo Tier 4 Final Diesel Generator, Model MP-V1100TP. 1100kW Twin Pack; Volvo TWD1672GE; Stamford S6L1D-G; SmartGen control panel: HGM; Smart Gen Controller HGH; 40' GP Soundproof/Weatherproof Containerized Enclosure with corrosion proofing package; High performance circuit breaker; Hardwire terminals; Chassis; Tier 4 Final; 8 hour base fuel tank; inbuilt 1600 Amp automatic transfer switch; 40' GP soundproof/weatherproof containerized enclosure chassis; Built-in ATS 1600AMP; 3/480V. Built 2024. With warranty.

    VIEW ITEM
  • Used MTU 1000 kW Standby Diesel Gen Set

    Used- MTU 1000 kW Standby Diesel Generator Set. MTU 16V2000 engine rated 1495 HP at 1800 RPM, SN-5362000574. 3/60/277/480V. main-line circuit breaker. Generator end has 180 hrs. Battery charger. Coolant heater. Open power unit. 17,596 Hrs. Year 1999.

    VIEW ITEM
  • Used 1000 kW Cummins QST30-G5 Diesel Generator – Tier 2

    Used- 1000 kW Cummins QST30-G5 Diesel Generator. EPA Tier 2. Sound-attenuated enclosure. Busbar M12. 2500 Amp Merlin Gerin Masterpact NW25 Micrologic 5.0 breaker. 340.3 gallon diesel base tank. 20 foot ISO container. 3phase/60hertz/277/480volt. 342 hours. 1505 Amps.1800 RPM. Year 2011.

    VIEW ITEM
  • Used Cummins QST30-G5 1000kW Diesel Generator – Tier 2, Industrial Power

    Used- Cummins 1000 kW Model QST30-G5 Diesel Generator. EPA Tier 2. Sound-attenuated enclosure. Busbar M12. 2500 Amp Merlin Gerin Masterpact NW25 Micrologic 5.0 breaker. 340.3 gallon diesel base tank. 20 foot ISO container. 3phase / 60hertz / 277/480 volt. 1505 Amps. 1800 RPM. Year 2011. 370 Hours.

    VIEW ITEM
  • Used 3.2 MW Cogeneration Plant – (4) Caterpillar G3516 Engines, Trane Chillers, Heat Recovery

    Used- 3.2 MW Cogeneration Plant;Includes: (4) Caterpillar G3516 SITA engines, mated to Caterpillar SR-4 or SR-4B generators rated at 800KW; 480V, 1200A. The plant is designed to run on Natural Gas with (2) 420 Ton Trane Absorption Chillers; (1) 630 Ton Trane Centrifugal Chiller, and (1) Recold chiller unit; All energy is recovered through a system of exhaust and cooling water heat recovery units. The units have wet exhaust systems that capture the exhaust heat, as well as the cooling water heat in a shell and tube heat exchanger (one for each generator). Exhaust gas temperature is approximately 800F, and block water enters the heat exchanger at 205F. After the heat exchanger, water enters the two absorption chillers at 230F. Engine intake water is approximately 200F after processing through the chillers. The (2) generator turbos are cooled through a closed cooling loop with a Recold unit. Mfg. 2009.

    VIEW ITEM
  • Used- MTU 600 kW Standby (550 kW prime) Diesel Generator Set - Model DS600

    Used- MTU 600 kW Standby (550 kW prime) Diesel Generator Set, Model DS600, SN-321178-1-1-0510. MTU 12V1600G80S engine rated 896 HP at 1800 RPM, SN-16701001344, EPA Tier 2 emissions. 3/60/120/208V, 12 lead reconnectable to other voltages. 2000 Amp adjustable main-line circuit breaker. PMG permanent magnet generator. Engine cooling radiator rated 50C/122F ambient. UL listed stationary engine generator assembly. Basler DGC-2020 digital control panel. Battery charger. Coolant heater. Weather enclosure. 1000 gallon sub-base fuel tank with secondary containment. 293 Hrs. Year 2010. 86W x 170L x 144H, 20,000 lbs. Passed load test 6/11/2024.

    VIEW ITEM
  • Used Caterpillar 600 kW Standby Diesel Generator Set – CAT 3412, 896 HP, 1159 Hrs

    Used- Caterpillar 600 kW Standby (545 kW prime) Diesel Generator Set. CAT 3412 engine rated 896 HP at 1800 RPM, SN-81Z19106. 3/60/277/480V, 12 lead reconnectable to other voltages. 1000 Amp main-line circuit breaker. EMCP II digital control panel. Battery charger. Coolant heater. Sound attenuated enclosure. 3400 gallon sub-base fuel tank with secondary containment. 1159 Hrs. Built 1996. Overall dimensions 114W x 313L x 160H 38,000 lbs. Passed load test 11/20/2024.

    VIEW ITEM
  • Used Hi-Power 500 kW Standby Generator – Perkins Engine, Low Hours, Load Bank Tested

    Used- Hi-Power 500 kW Standby Unit. Perkins Engine rated 432.5 bkW. Sound Attenuated. 920 gallon base fuel tank. 3/60/480. 1800 RPM. 705 hours. Load Banked Tested! Passed with No Issues. Trailer can be purchased with unit for additional cost.

    VIEW ITEM
  • Unused Caterpillar 455 kW Standby Generator Set – CAT C18 Engine

    Unused- Caterpillar 455 kW Standby Generator Set. CAT C18 Engine. 1800 RPM. Control Panel. Open skid unit. 3/60/480 Volt.

    VIEW ITEM
  • Caterpillar Model C18 455kW Industrial Generator

    Unused- CAT 455Kw generator, Model 455. CAT Engine, model C18, Open skid unit.

    VIEW ITEM
  • Unused Caterpillar 455 kW Standby Industrial Generator Set with CAT C18 Engine

    Unused- Caterpillar 455 kW Standby Industrial Generator Set. CAT C18 Engine. 1800 RPM. Control Panel. Open skid unit. 3/60/480 Volt.

    VIEW ITEM
  • Used CAT Model C15 Engine 400kW Diesel Generator | Ready To Ship

    Used Caterpillar 400 kW (365 kW prime) Standby Diesel Generator Set, SN-C5E03099. CAT C15 engine rated 619 HP at 1800 RPM, SN-FSE03694, EPA Tier 3 emissions. 3/60/277/480V, 12 lead reconnectable to other voltages. 800 Amp main-line circuit breaker. PMG - Permanent magnet generator. EMCP 3.2 digital control panel. UL listed package. Sens battery charger. Coolant heater. Weather enclosure. 400 gallon sub-base fuel tank with secondary containment. 429 Hrs. Year 2011. CAT Worldwide ESC warranty 1-5 years available at additional cost. Passed load test 1/24/2025.

    VIEW ITEM
  • Triton 350 kW Used Triton 350 kW Diesel Generator – Volvo Engine, Trailer-Mounted, Low Hours

    Used- Triton 350 kW Generator. Volvo Engine. Weather-proof enclosure. 1000 Gallon DW Base Fuel Tank; Magna Plus Gen Head; Block Heater; Auto Start SDMO Control Panel. Display screen has faded. New tires on trailer. 3/60/480. 1800 RPM. Approx. 1000 hours. Can be sold without trailer for discounted price.

    VIEW ITEM
  • Generac Natural Gas Generator, Model MG0300

    Used- Generac Natural Gas Generator, Model MG0300. 300 KW. Enclosed OH0924 Engine. Built 2012. 3/60/277/480V. 160 hours. Serial# 2114542.

    VIEW ITEM
  • Unused Cummins 300 kW Natural Gas Standby Generator Set – Model C300N6

    Unused- Natural Gas, Cummins 300 kW Standby Generator Set, Model C300N6. Cummins GTA GTA855EICS 14L engine rated 470 HP at 1800 RPM. EPA certified. 3/60/277/480V, 12 lead reconnectable to other voltages. 600 Amp 100% rated main-line circuit breaker. PMG permanent magnet generator. UL 2200 listed package. Cummins Power Command 3.3 MLD utility-rated paralleling digital control panel. Sens battery charger 12 amp 120/208/240V. Coolant heater 2500W. Catalyst, 5 in flange, NSPS 2/4/1. Level 2 sound attenuated aluminum enclosure 100 MPH wind rating. 0 Hours. Built 2024. Cummins 2 Yr 1000 Hr limited warranty. Overall dimensions 70W x 281L x 97H on 6H blocks, 10,970 lbs.

    VIEW ITEM
  • Used Multiquip 250/275 kW Diesel Generator – Iveco Engine, Low Hours, Weatherproof

    Used- Multiquip 250/275kW Generator. Iveco Engine. WP Enclosure; 1600 DW Base Fuel Tank; Magna Plus Gen Head; Main Breaker; Block Heater; Auto Start Control Panel. 3/60/480. 1800 RPM. 750 Hours.

    VIEW ITEM
  • Cummins Standby Natural Gas Generator, Model 235GFBC

    Used- Cummins Standby Natural Gas Generator, Model 235GFBC. Rated 235 kW. With enclosure. Cummins model GTA855G3 engine Serial# 25303054, Approximately 354hp. 3/60/480V, 1800 RPM. Built 2005. 920 hours.

    VIEW ITEM
  • Cummins Model GGLB 150 kW Standby Natural Gas / Propane Generator

    Used- Cummins 150 kW Standby Natural Gas / Propane Generator Set, Model GGLB, SN-D060916175. GM 8.1L engine rated 225 HP at 1800 RPM, 3/60/277/480V. 400 Amp main-line circuit breaker. PMG - permanent magnet generator. UL 2200 listed package. Oversized generator end rated 180 kW. PowerCommand 2100 digital control panel. Coolant heater. Sound attenuated enclosure. 1159 Hrs. Built 2006.

    VIEW ITEM
  • Cummins Model DSHAA 150kW Standby Diesel Generator

    Used- Cummins 150 kW Standby (135 kW prime) Diesel Generator, Model DSHAA, SN-D060916181. Cummins QSL9-G2 engine rated 364 HP at 1800 RPM, SN-46580071, EPA Tier 3 emissions. 225 Amp main-line circuit breaker. 3/60/277/480V, 12 lead reconnectable to other voltages. Oversized generator end rated 180 kW. PowerCommand 2100 digital control panel. UL 2200 listed stationary engine-generator assembly. Sound attenuated enclosure. 366 gallon UL listed sub-base fuel tank w/secondary containment. 610 Hrs. Year 2006.

    VIEW ITEM
  • Used SDMO/John Deere 155 kVA Diesel Generator – Trailerized, Prime Power, Low Hours

    Used- SDMO/John Deere Diesel Rental Grade Trailerized Unit. 155Kva/128Kw. Set for Continuous Prime Power. Selector Switch for Multi Voltages; Sound Attenuated Enclosure; Main Breaker on Deck; Gang Box on Rear for Storage of Cables; Tandem Axle Trailer; (2) Spare Tires on Deck; Cam Loc Cables on Deck; Auto Start or Manual Start; Lock Key Box on Deck; Block Heater; Battery Charger. Built 2007. 1142 Hours. Batteries may be dead.

    VIEW ITEM
  • Used John Deere / SDMO 155 kVA Diesel Generator – Portable - Prime Power -Low Hours

    Used- John Deere / SDMO Diesel Rental Grade Trailerized Unit, 155Kva/128Kw. Set for Continuous Prime Power. Selector Switch for Multi Voltages; Sound Attenuated Enclosure; Main Breaker on Deck; Gang Box on Rear for Storage of Cables; Tandem Axle Trailer; (2) Spare Tires on Deck; Cam Loc Cables on Deck; Auto Start or Manual Start; Lock Key Box on Deck; Block Heater; Battery Charger. 873 Hours. Batteries may be dead.

    VIEW ITEM
  • Kohler Standby Natural Gas Generator, Model 125REZGC.

    Used- Kohler Standby Natural Gas Generator, Model 125REZGC. Rated 125 kW. With enclosure. 1800 RPM. 3/60/277/480V. Built 2013. 2167 hours.

    VIEW ITEM
  • Olympian Model D100P1 Mobile Diesel Generator, 100kW

    Used- Portable / Trailerized Olympian Diesel Generator, Model D100P1. Rated 100 kW. 1800RPM, 166 HP, 3/60/120/208V Perkins Engine. Built 2001. 70 hours. All fluids recently changed and load tested.

    VIEW ITEM
  • Olympian 75kW Standby Natural Gas Generator Set

    Used- Olympian 75kW Standby Natural Gas Generator Set, Model G80F3. Ford engine model WSG1068I6005E-NA, approximate 112HP, 1800 RPM, SN-03-09-060446. Weather enclosure. 3/60/120/208 Volt. 577 hours. Serial# OLY00000JNFC01262, Built 2003.

    VIEW ITEM
  • Used Cummins 75 kW Standby Natural Gas / Propane Generator Set – Model GGHF

    Used- Cummins 75 kW Standby Natural Gas / Propane Generator Set, Model GGHF - 5756500, SN-C060905687. Ford WSG1068 6.8L engine rated 126 HP at 1800 RPM, SN-06YS53164. 1/60/120/240V single phase. 350 Amp main-line circuit breaker. UL listed package. PowerCommand digital control panel. EnerGenius battery charger. Coolant heater. Sound attenuated enclosure. 418 Hrs.

    VIEW ITEM
  • Used Multiquip Diesel DCA-125SSJU Trailerized Generator – 72 kW, 3-Phase, 240/480V

    Used- Multiquip Trailerized Diesel Generator, Model DCA-125SSJU. Rated 72 kW; 3/60/240/480V; 150 HP, 1800 RPM John Deere 6068TF engine; 227 hours.

    VIEW ITEM
  • Used Trailerized Multiquip Model DCA-70SSIU2fDiesel Generator

    Used- Multiquip Trailerized Diesel Generator, Model DCA-70SSIU2. Rated 56 kW; 3/60/240/480V; 85 HP, 1800 RPM Isuzu 4JJ1x engine; 1774 hours.

    VIEW ITEM
  • 2023 Cummins C50D6C Generator 50kW

    Unused- 2023 Cummins C50D6C Generator 50kW. Open skid 120/208 volt 3 phase 60 hz Diesel generator 50 Gallon Pryco Day Tank Generator breaker 70amp / 125amp / 175 amp 2 / ATS 125 AMP and 70 AMP Split loads Exhaust System with Particulate filter. 3

    VIEW ITEM
  • Onan 35 kW Natural Gas Generator Set: Reliable Standby Power Solution

    Used- Cummins / Onan 35 kW Standby Natural Gas Generator Set, Model 35SJB, SN-L900363017. Chrysler model H135 engine, SN-K1142033, 3600rpm. Rated 35 kW, 3/60/277/480V 12 lead reconnectable to other voltages.. 60 Amp main-line circuit breaker. Hours 403. No enclosure.

    VIEW ITEM
  • Used Multiquip DCA-25USI2 Trailerized Diesel Generator – 20 kW, 3-Phase, 240/480V

    Used- Multiquip Trailerized Diesel Generator, Model DCA-25USI2. Rated 20 kW; 3/60/240/480V; 30.6 HP, 1800 RPM Isuzu 4LE2 engine; 74 hours.

    VIEW ITEM
  • Used Caterpillar C280-8 Offshore Diesel Generator Set – 2200 kW, Kato Generator, 900 RPM

    Used-Caterpillar Offshore Generator Set, Model C280-8, Diesel Engine 3608, I-8 4-Stroke-Cycle-Diesel. Rated Speed: 900 RPM; Kato Engineering Generator; Model AA28661000; Potency: 3.142,9 Kwa / 2.200 Kw, 3 phase, 60Hz, 346/600 Volts, 3.024 Ah.

    VIEW ITEM
  • Caterpillar C280-8 Offshore Diesel Generator Set – 2200 kW, Kato Generator, 900 RPM

    Used Caterpillar Model C280-8 Offshore Generator Set. Diesel Engine Model 3608, I-8 4-Stroke-Cycle-Diesel. Rated Speed: 900 RPM; Kato Engineering Generator; Model AA28661000; Potency: 3.142,9 Kwa / 2.200 Kw, 3 phase, 60Hz, 346/600 Volts, 3.024 Ah.

    VIEW ITEM
Cash Icon
Surplus Equipment?

We pay "Top Dollar" for your idle process equipment! Fill out our form and our buying team will get back to you.

SELL YOUR EQUIPMENT
Search Icon
Browse Inventory

View our entire process equipment inventory online or visit our location for an equipment inspection.

View Inventory
Phone Icon
Contact Us

Contact Us

630-350-2200