Your Files Are Being Processed
Please Wait
Contact Information
Phone: 630-350-2200
Toll Free: 1-800-49-AARON
Email: [email protected]
Used General Electric Steam Turbine-Generator. 66,086 kW rated straight condensing steam turbine and an 80,300 kVA rated generator, including its auxiliary systems and the condenser system. Condenser is a Graham water cooled condenser with a duty of 434.83 x 106 btu/lb, exhaust pressure of 2.24” HgA and turbine exhaust flow of 481,020 lb./hr. The inlet steam conditions are 850psig/825F and the inlet is sized for a guaranteed flow of 573,334 pph. The max expected flow (not guaranteed) is 641,446 pph of steam flow. The turbine inlet flange is 12”-900# and is oversized such that it could be upgraded to pass up to 660,000 pph of 850psig/825FF steam or an increase of 15% increase over design, if needed for reapplication. The 641,446 pph “expected: flow rating is at “valves wide open”. The generator is a GE H2 cooled, 80,300 kVA, 13,800 v, 2 pole generator with a .85 PF and a .56 short circuit ration. Rating is based on a 30psig H2 pressure, with a 115F H2 temperature and a 100F cooling water temperature. Based on the GE generator inspection report from 2013 this generator has modern 18Mn-18Cr retaining ring material to meet the reliability and insurance company requirements. Graham Manufacturing 58,691 square foot surface area condenser. Bently Nevada 3300 series probes and devices for monitoring alarm and trip funtions. New GE EX2100e digital control system. Built in 1991, shipped in 1992, and major overhaul in 2013.
"Dealing with Aaron is an easy and enjoyable process"
"Aaron Equipment is always my first call for used process equipment. Their inventory and customer service has ensured successful project results every time. Thanks y’all!"
"I have purchased all different types of equipment from Aaron Equipment over the last 10 years and have always been 100% happy with not only the equipment but with their customer service!"
"Working with Aaron Equipment Company was as easy as it gets."
"It is a pleasure to work with AEK and I would recommend them as an equipment supplier."
"The partnership we enjoy with Aaron has helped our business to be what it is today – thank you guys!”
"I will definitely use Aaron Equipment in the future."
"Aaron’s customer service indicates that they want long term partnerships and that is something we especially appreciate."
"I really value shopping for used equipment from Aaron Equipment Company because the information they present is accurate, their prices fair and their customer service is the best…Highly recommend."
"This is my first time using Aaron Equipment to purchase equipment. They were easy to work with and things were done quickly and efficiently. I will be a repeat customer when the need arises. This is a trustworthy company that delivers what they advertise."
"I have purchased multiple pieces of equipment through Aaron equipment over the past 15 years. The staff has been very knowledgeable on every request & have spent countless hours ensuring that the equipment I was purchasing met my expectations."
"I have been doing business with Aaron equipment for many years. This year I had the need for some used equipment in a new business Venture. I got in touch with Ryan Davies. I could not be happier with the response and honesty exhibited by him. Dealing with them was a pleasure and everything was as represented. Fair an Honest is how I would describe them."
“Aaron Equipment was very easy to get into contact with and get a price on a un-used chiller they were selling. The process was seamless and very easy on our end and we had the equipment much faster than going out for bid on it to multiple vendors and we able to come in under budget on the project.”
Used General Electric Steam Turbine-Generator. 66,086 kW rated straight condensing steam turbine and an 80,300 kVA rated generator, including its auxiliary systems and the condenser system. Condenser is a Graham water cooled condenser with a duty of 434.83 x 106 btu/lb, exhaust pressure of 2.24” HgA and turbine exhaust flow of 481,020 lb./hr. The inlet steam conditions are 850psig/825F and the inlet is sized for a guaranteed flow of 573,334 pph. The max expected flow (not guaranteed) is 641,446 pph of steam flow. The turbine inlet flange is 12”-900# and is oversized such that it could be upgraded to pass up to 660,000 pph of 850psig/825FF steam or an increase of 15% increase over design, if needed for reapplication. The 641,446 pph “expected: flow rating is at “valves wide open”. The generator is a GE H2 cooled, 80,300 kVA, 13,800 v, 2 pole generator with a .85 PF and a .56 short circuit ration. Rating is based on a 30psig H2 pressure, with a 115F H2 temperature and a 100F cooling water temperature. Based on the GE generator inspection report from 2013 this generator has modern 18Mn-18Cr retaining ring material to meet the reliability and insurance company requirements. Graham Manufacturing 58,691 square foot surface area condenser. Bently Nevada 3300 series probes and devices for monitoring alarm and trip funtions. New GE EX2100e digital control system. Built in 1991, shipped in 1992, and major overhaul in 2013.
We pay "Top Dollar" for your idle process equipment! Fill out our form and our buying team will get back to you.
SELL YOUR EQUIPMENTView our entire process equipment inventory online or visit our location for an equipment inspection.
View Inventory