hit counter

Your Files Are Being Processed

70% Complete

Please Wait

Tell Us What Process Equipment You Have For Sale SELL YOUR EQUIPMENT

Used Steam Turbine Generators

Below is Aaron's inventory of unused and used steam turbine generators. If you are looking to sell your used steam turbine generator submit a request online or contact Erik Eichert at 630-238-7480.

6 Steam Turbine Generators

Enter to Search

Used- Elliott Steam Turbine

Used- Elliott Steam Turbine, Model 2DYR5PE III. Normal Conditions: 2150.0 KWE Rated Power, 5706 RPM Rated Speed, 13,800 Volt, 600.0 PSIG Normal Inlet Pressure, 750.0 Degrees F Normal Inlet Temperature. Hyundai Ideal Brushless AC Generator, 2000 kW, 2500 Kva, 1800 RPM, 125 DC Volt Brushless Exciter, 1.1 kW Permanent Magnet Altern more info...

Used- Elliott Mulit-Stage Steam Turbine, Model 2DYRPE3

Used- Elliott Mulit-Stage Steam Turbine, Model 2DYRPE3, Rated power 2148kw, 2050 kw generator output. Speed 5620 rpm, tip speed 6182 rpm, inlet 464 psig at 662 degrees F. 3/60/4160 Volt. Stamford AC generator model P1734C. Skid mounted. Serial# E102715, built 2002.

Unused- Fuji Electric Condensing Steam Turbine Generator System

Stock# 50548001

Unused- Fuji Electric Condensing Steam Turbine Generator System. Consisting of: 9.4 MW Steam Turbine, Generator, Reduction Gear, Brushless Exciter, 900 psig Main Steam Pressure, 825 degrees F, 1.227 psig Condenser Vacuum, 13,800 Volt, 3/60 Hz, 5985 rpm; 1.9 MW Back Pressure Condensing Steam Turbine, Generator, Reduction Gear, Br more info...

Used- Siemens 12 MW Steam Generator

Used- Siemens 12 MW Steam Turbine, Model Condensing, Model is SST150. Inlet Pressure: 64 kg/cm2. Inlet Temperature: 480 Degree C. Bleed Pressure 4.43 kg/cm2. Bleed Temperature: 187 Degree C. Bleed Flow: 6.13 ton at full load. Exhaust pressure: 0.106 ata. Includes CPC, control oil piping, high speed coupling with guard. New year more info...

Used- MAN Turbo 16 MW Steam Turbine Generator Assembly, Model MARC4-B00.

Stock# 49493001

Used- MAN Turbo 16 MW Steam Turbine Generator Assembly, Model MARC4-B00. 12,000 - 26,800 hp. Maximum flange diameter, live steam up to 250 mm, exhaust up to 1,500 mm. Maximum live steam conditions, 120 bar(a) / 520 degree C, 1,740 psi(a) / 968 degree F. 7,000 - 10,000 rpm. Includes: Jeumont electric generator, Model JISALT DECA more info...

Used- Westinghouse Electric Corporation Two Cylinder Tandem Compound Condensing

Stock# 49769001

Used- Westinghouse Electric Corporation Two Cylinder Tandem Compound Condensing Reheat Turbine. At rated speed pf 3600 rpm the unit is designed for 60,000 kW, 0.80 power factory, 75,000 kW maximum rating, when supplied with steam at 1450 psi gauge throttle pressure, 1000 degrees F total temperature with reheat at 1000 degrees F more info...

Used- Elliott Steam Turbine

Used- Elliott Steam Turbine

Stock# 51095001

Used- Elliott Steam Turbine, Model 2DYR5PE III. Normal Conditions: 2150.0 KWE Rated Power, 5706 RPM Rated Speed, 13,800 Volt, 600.0 PSIG Normal Inlet Pressure, 750.0 Degrees F Normal Inlet Temperature. Hyundai Ideal Brushless AC Generator, 2000 kW, 2500 Kva, 1800 RPM, 125 DC Volt Brushless Exciter, 1.1 kW Permanent Magnet Alternator. Control Cabinet with Allen-Bradley PanelView Plus 1000 Touch Screen and Woodward 505 Turbine Control Screen. SEL Generator Protection Relay, Model SEL-700G and Basler Digital Excitation Control System. Built 2011. Reported to be reconditioned.

KW: 2000 Mfr: Elliott RPM: 5706 Volts: 13800

Standard Terms and Conditions

VIEW ITEM

Used- Elliott Mulit-Stage Steam Turbine, Model 2DYRPE3

Used- Elliott Mulit-Stage Steam Turbine, Model 2DYRPE3

Stock# 50895037

Used- Elliott Mulit-Stage Steam Turbine, Model 2DYRPE3, Rated power 2148kw, 2050 kw generator output. Speed 5620 rpm, tip speed 6182 rpm, inlet 464 psig at 662 degrees F. 3/60/4160 Volt. Stamford AC generator model P1734C. Skid mounted. Serial# E102715, built 2002.

KW: 2148 Mfr: Elliot RPM: 5620 Volts: 4160

Standard Terms and Conditions

VIEW ITEM

Unused- Fuji Electric Condensing Steam Turbine Generator System

Unused- Fuji Electric Condensing Steam Turbine Generator System

Stock# 50548001

Unused- Fuji Electric Condensing Steam Turbine Generator System. Consisting of: 9.4 MW Steam Turbine, Generator, Reduction Gear, Brushless Exciter, 900 psig Main Steam Pressure, 825 degrees F, 1.227 psig Condenser Vacuum, 13,800 Volt, 3/60 Hz, 5985 rpm; 1.9 MW Back Pressure Condensing Steam Turbine, Generator, Reduction Gear, Brushless Exciter, 900 psig, 825 degrees F, 13,800 Volt, 3/60 Hz. Built 1987.

KW: 9400 Mfr: Fuji RPM: 5985 Volts: 13800
VIEW ITEM ADD TO CART

Used- Siemens 12 MW Steam Generator

Used- Siemens 12 MW Steam Generator

Stock# 50661001

Used- Siemens 12 MW Steam Turbine, Model Condensing, Model is SST150. Inlet Pressure: 64 kg/cm2. Inlet Temperature: 480 Degree C. Bleed Pressure 4.43 kg/cm2. Bleed Temperature: 187 Degree C. Bleed Flow: 6.13 ton at full load. Exhaust pressure: 0.106 ata. Includes CPC, control oil piping, high speed coupling with guard. New year 2005. Commissioned in year 2007.

KW: 12000 Mfr: Siemens RPM: Volts:

Standard Terms and Conditions

VIEW ITEM

Used- MAN Turbo 16 MW Steam Turbine Generator Assembly, Model MARC4-B00.

Used- MAN Turbo 16 MW Steam Turbine Generator Assembly, Model MARC4-B00.

Stock# 49493001

Used- MAN Turbo 16 MW Steam Turbine Generator Assembly, Model MARC4-B00. 12,000 - 26,800 hp. Maximum flange diameter, live steam up to 250 mm, exhaust up to 1,500 mm. Maximum live steam conditions, 120 bar(a) / 520 degree C, 1,740 psi(a) / 968 degree F. 7,000 - 10,000 rpm. Includes: Jeumont electric generator, Model JISALT DECA 419. Renk Gearbox/transmission, Model CPG 100z/3M. Hydac control oil system, Model ISO-VG 46 DIN51515. Reinhold Wesselmann lubrication system. Approximately 60,000 hours.

KW: 16000 Mfr: RPM: 10000 Volts:
VIEW ITEM ADD TO CART

Used- Westinghouse Electric Corporation Two Cylinder Tandem Compound Condensing

Used- Westinghouse Electric Corporation Two Cylinder Tandem Compound Condensing

Stock# 49769001

Used- Westinghouse Electric Corporation Two Cylinder Tandem Compound Condensing Reheat Turbine. At rated speed pf 3600 rpm the unit is designed for 60,000 kW, 0.80 power factory, 75,000 kW maximum rating, when supplied with steam at 1450 psi gauge throttle pressure, 1000 degrees F total temperature with reheat at 1000 degrees F total temperature and 1.0 Hg absolute exhaust pressure. Turbine #: H.P. 5-A7080-1, LP 5A-7081-1, 60,000 kW, 3600 rpm, 36 stages. Generator #: 1-S-35-P-725, 75,000 kva, 3600 rpm, 13,800 volts, 0.5 psig H2 press. Main Exciter: 225 kW, 3600 rpm, 250 volts. Pilot Exciter: 2.5 kW, 3600 rpm, 250 volts. Complete self-contained lubricating oil system is furnished. It consists of an oil reservoir of 3000 gallons capacity with strainer. Based on receiving steam at 1450 psig and 1000 degrees F, total temperature reheating to 1000 degrees F total temperature and exhausting at 29" hg vacuum and with full steam extraction for feedwater heating, the unit is guaranteed to generate 75,000 kW at unity power factor with a steam flow to throttle of 511,500 pounds per hour or 6.82 pounds of steam per kilowatt hour. The base rating of the generator is 60,000 kW with 0.5 psig hydrogen, 80% power factor, 75,000 kva, 13,800 volts, wye connected, 3 phase, 60 cycle, 0.90 short circuit ration, 3600 rpm, with class B insulation. The generator is totally enclosed and is cooled by hydrogen which is circulated by blowers mounted on the generator casing. The cooling system is designed for up to 30 psig operating pressure.

KW: 75000 Mfr: Westinghouse RPM: 3600 Volts: 13800
VIEW ITEM ADD TO CART
  • Used- Elliott Steam Turbine

    Used- Elliott Steam Turbine, Model 2DYR5PE III. Normal Conditions: 2150.0 KWE Rated Power, 5706 RPM Rated Speed, 13,800 Volt, 600.0 PSIG Normal Inlet Pressure, 750.0 Degrees F Normal Inlet Temperature. Hyundai Ideal Brushless AC Generator, 2000 kW, 2500 Kva, 1800 RPM, 125 DC Volt Brushless Exciter, 1.1 kW Permanent Magnet Alternator. Control Cabinet with Allen-Bradley PanelView Plus 1000 Touch Screen and Woodward 505 Turbine Control Screen. SEL Generator Protection Relay, Model SEL-700G and Basler Digital Excitation Control System. Built 2011. Reported to be reconditioned.

    VIEW ITEM
  • Used- Elliott Mulit-Stage Steam Turbine, Model 2DYRPE3

    Used- Elliott Mulit-Stage Steam Turbine, Model 2DYRPE3, Rated power 2148kw, 2050 kw generator output. Speed 5620 rpm, tip speed 6182 rpm, inlet 464 psig at 662 degrees F. 3/60/4160 Volt. Stamford AC generator model P1734C. Skid mounted. Serial# E102715, built 2002.

    VIEW ITEM
  • Unused- Fuji Electric Condensing Steam Turbine Generator System

    Unused- Fuji Electric Condensing Steam Turbine Generator System. Consisting of: 9.4 MW Steam Turbine, Generator, Reduction Gear, Brushless Exciter, 900 psig Main Steam Pressure, 825 degrees F, 1.227 psig Condenser Vacuum, 13,800 Volt, 3/60 Hz, 5985 rpm; 1.9 MW Back Pressure Condensing Steam Turbine, Generator, Reduction Gear, Brushless Exciter, 900 psig, 825 degrees F, 13,800 Volt, 3/60 Hz. Built 1987.

    VIEW ITEM
  • Used- Siemens 12 MW Steam Generator

    Used- Siemens 12 MW Steam Turbine, Model Condensing, Model is SST150. Inlet Pressure: 64 kg/cm2. Inlet Temperature: 480 Degree C. Bleed Pressure 4.43 kg/cm2. Bleed Temperature: 187 Degree C. Bleed Flow: 6.13 ton at full load. Exhaust pressure: 0.106 ata. Includes CPC, control oil piping, high speed coupling with guard. New year 2005. Commissioned in year 2007.

    VIEW ITEM
  • Used- MAN Turbo 16 MW Steam Turbine Generator Assembly, Model MARC4-B00.

    Used- MAN Turbo 16 MW Steam Turbine Generator Assembly, Model MARC4-B00. 12,000 - 26,800 hp. Maximum flange diameter, live steam up to 250 mm, exhaust up to 1,500 mm. Maximum live steam conditions, 120 bar(a) / 520 degree C, 1,740 psi(a) / 968 degree F. 7,000 - 10,000 rpm. Includes: Jeumont electric generator, Model JISALT DECA 419. Renk Gearbox/transmission, Model CPG 100z/3M. Hydac control oil system, Model ISO-VG 46 DIN51515. Reinhold Wesselmann lubrication system. Approximately 60,000 hours.

    VIEW ITEM
  • Used- Westinghouse Electric Corporation Two Cylinder Tandem Compound Condensing

    Used- Westinghouse Electric Corporation Two Cylinder Tandem Compound Condensing Reheat Turbine. At rated speed pf 3600 rpm the unit is designed for 60,000 kW, 0.80 power factory, 75,000 kW maximum rating, when supplied with steam at 1450 psi gauge throttle pressure, 1000 degrees F total temperature with reheat at 1000 degrees F total temperature and 1.0 Hg absolute exhaust pressure. Turbine #: H.P. 5-A7080-1, LP 5A-7081-1, 60,000 kW, 3600 rpm, 36 stages. Generator #: 1-S-35-P-725, 75,000 kva, 3600 rpm, 13,800 volts, 0.5 psig H2 press. Main Exciter: 225 kW, 3600 rpm, 250 volts. Pilot Exciter: 2.5 kW, 3600 rpm, 250 volts. Complete self-contained lubricating oil system is furnished. It consists of an oil reservoir of 3000 gallons capacity with strainer. Based on receiving steam at 1450 psig and 1000 degrees F, total temperature reheating to 1000 degrees F total temperature and exhausting at 29" hg vacuum and with full steam extraction for feedwater heating, the unit is guaranteed to generate 75,000 kW at unity power factor with a steam flow to throttle of 511,500 pounds per hour or 6.82 pounds of steam per kilowatt hour. The base rating of the generator is 60,000 kW with 0.5 psig hydrogen, 80% power factor, 75,000 kva, 13,800 volts, wye connected, 3 phase, 60 cycle, 0.90 short circuit ration, 3600 rpm, with class B insulation. The generator is totally enclosed and is cooled by hydrogen which is circulated by blowers mounted on the generator casing. The cooling system is designed for up to 30 psig operating pressure.

    VIEW ITEM
Cash Icon
Surplus Equipment?

We pay "Top Dollar" for your idle process equipment! Fill out our form and our buying team will get back to you.

SELL YOUR EQUIPMENT
Search Icon
Browse Inventory

View our entire process equipment inventory online or visit our location for an equipment inspection.

View Inventory
Phone Icon
Contact Us

Email or call us to speak with an equipment specialist to answer any machinery questions you may have.

630-350-2200