Unused - 450MW Hitachi TC4F-26 Steam Turbine Generator. Nominal rating 400MW. Max continuous rating 450MW, Type TC4R-26, 2,400psig, 1,000F, reheat steam 1,000F, exhaust pressure 2.5 inch Hg. Abs., 3,600rpm, 7 extractions, number of stages: HP 6, IP 4, LP 7x four flow, last stage bucket height 26in., governor type: fly ball with rotation pilot valve, 2 main stop valves, 4 control valves, 2 combined reheat valves, casing: 3 number double wall construction, rotor: 3 number solid type, journal bearings: 4 number elliptical, thrust bearing: 1 number tapered - land type, shaft gland system: steam seal with labyrinth packing, turbine governing device, mechanical hydraulic governor, generator: TFLQQ-K totally enclosed, explosion proof, cylindrical rotor type. AC generator, with water cooled stator, and hydrogen direct cooled rotor, outdoor type, rated capacity 553,064 kVA at 60psig hydrogen, .85 power factor, rated output: 470,104kW at 60psig hydrogen, terminal voltage 24,000V, 3 phases, 60Hz. double star connection. Built 1976.
Manufacturer | HitachiHitachi |
Model | TC4F-26 |
Category | GeneratorsGenerators |
Subcategory | Steam TurbineSteam Turbine |
Manufacturer:
Hitachi
Description:
For sale: Unused Hitachi TC4F-26 Steam Turbine Generator with a nominal rating of 400 MW and a maximum continuous rating of 450 MW. This high-capacity turbine operates at 2,400 psig inlet pressure with 1,000°F main steam and 1,000°F reheat steam. Designed for efficient power generation, it runs at 3,600 RPM with an exhaust pressure of 2.5 inches Hg Abs.
The turbine features 7 extractions and a multi-stage configuration: 6 HP stages, 4 IP stages, and 7x four-flow LP stages with a last stage bucket height of 26 inches. The fly ball governor with a rotation pilot valve ensures precise control, supported by 2 main stop valves, 4 control valves, and 2 combined reheat valves.
Constructed with a three-number double-wall casing and three-number solid-type rotors, the unit includes journal bearings for reliable performance.
Specifications:
Steam Turbine:
Manufacturer: Hitachi
Model: TC4F-26 / Type TC4R-26
Nominal Rating: 400 MW
Max Continuous Rating: 450 MW
Inlet Steam Pressure: 2,400 psig
Main Steam Temperature: 1,000°F
Reheat Steam Temperature: 1,000°F
Exhaust Pressure: 2.5 inches Hg Abs
Speed: 3,600 RPM
Extractions: 7
Stages: HP – 6, IP – 4, LP – 7x four-flow
Last Stage Bucket Height: 26 inches
Control & Valve System:
Governor Type: Fly ball with rotation pilot valve
Main Stop Valves: 2
Control Valves: 4
Combined Reheat Valves: 2
Construction:
Casing: 3-number double-wall construction
Rotor: 3-number solid type
Bearings: Journal bearings
Applications:
Utility-scale power plants
Industrial steam power generation
Combined cycle power plants
Large-scale energy projects
What Products Would This Be Used For?
High-capacity electricity generation
Base load and peak load power plants
Industrial steam and power solutions
Grid-connected energy projects
450MW generator, Steam Turbine, Steam turbine generator, Unused generator
"Dealing with Aaron is an easy and enjoyable process"
"Aaron Equipment is always my first call for used process equipment. Their inventory and customer service has ensured successful project results every time. Thanks y’all!"
"I have purchased all different types of equipment from Aaron Equipment over the last 10 years and have always been 100% happy with not only the equipment but with their customer service!"
"Working with Aaron Equipment Company was as easy as it gets."
"It is a pleasure to work with AEK and I would recommend them as an equipment supplier."
"The partnership we enjoy with Aaron has helped our business to be what it is today – thank you guys!”
"I will definitely use Aaron Equipment in the future."
"Aaron’s customer service indicates that they want long term partnerships and that is something we especially appreciate."
"I really value shopping for used equipment from Aaron Equipment Company because the information they present is accurate, their prices fair and their customer service is the best…Highly recommend."
"This is my first time using Aaron Equipment to purchase equipment. They were easy to work with and things were done quickly and efficiently. I will be a repeat customer when the need arises. This is a trustworthy company that delivers what they advertise."
"I have purchased multiple pieces of equipment through Aaron equipment over the past 15 years. The staff has been very knowledgeable on every request & have spent countless hours ensuring that the equipment I was purchasing met my expectations."
"I have been doing business with Aaron equipment for many years. This year I had the need for some used equipment in a new business Venture. I got in touch with Ryan Davies. I could not be happier with the response and honesty exhibited by him. Dealing with them was a pleasure and everything was as represented. Fair an Honest is how I would describe them."
“Aaron Equipment was very easy to get into contact with and get a price on a un-used chiller they were selling. The process was seamless and very easy on our end and we had the equipment much faster than going out for bid on it to multiple vendors and we able to come in under budget on the project.”
Unused - 450MW Hitachi TC4F-26 Steam Turbine Generator. Nominal rating 400MW. Max continuous rating 450MW, Type TC4R-26, 2,400psig, 1,000F, reheat steam 1,000F, exhaust pressure 2.5 inch Hg. Abs., 3,600rpm, 7 extractions, number of stages: HP 6, IP 4, LP 7x four flow, last stage bucket height 26in., governor type: fly ball with rotation pilot valve, 2 main stop valves, 4 control valves, 2 combined reheat valves, casing: 3 number double wall construction, rotor: 3 number solid type, journal bearings: 4 number elliptical, thrust bearing: 1 number tapered - land type, shaft gland system: steam seal with labyrinth packing, turbine governing device, mechanical hydraulic governor, generator: TFLQQ-K totally enclosed, explosion proof, cylindrical rotor type. AC generator, with water cooled stator, and hydrogen direct cooled rotor, outdoor type, rated capacity 553,064 kVA at 60psig hydrogen, .85 power factor, rated output: 470,104kW at 60psig hydrogen, terminal voltage 24,000V, 3 phases, 60Hz. double star connection. Built 1976.
Manufacturer:
Hitachi
Description:
For sale: Unused Hitachi TC4F-26 Steam Turbine Generator with a nominal rating of 400 MW and a maximum continuous rating of 450 MW. This high-capacity turbine operates at 2,400 psig inlet pressure with 1,000°F main steam and 1,000°F reheat steam. Designed for efficient power generation, it runs at 3,600 RPM with an exhaust pressure of 2.5 inches Hg Abs.
The turbine features 7 extractions and a multi-stage configuration: 6 HP stages, 4 IP stages, and 7x four-flow LP stages with a last stage bucket height of 26 inches. The fly ball governor with a rotation pilot valve ensures precise control, supported by 2 main stop valves, 4 control valves, and 2 combined reheat valves.
Constructed with a three-number double-wall casing and three-number solid-type rotors, the unit includes journal bearings for reliable performance.
Specifications:
Steam Turbine:
Manufacturer: Hitachi
Model: TC4F-26 / Type TC4R-26
Nominal Rating: 400 MW
Max Continuous Rating: 450 MW
Inlet Steam Pressure: 2,400 psig
Main Steam Temperature: 1,000°F
Reheat Steam Temperature: 1,000°F
Exhaust Pressure: 2.5 inches Hg Abs
Speed: 3,600 RPM
Extractions: 7
Stages: HP – 6, IP – 4, LP – 7x four-flow
Last Stage Bucket Height: 26 inches
Control & Valve System:
Governor Type: Fly ball with rotation pilot valve
Main Stop Valves: 2
Control Valves: 4
Combined Reheat Valves: 2
Construction:
Casing: 3-number double-wall construction
Rotor: 3-number solid type
Bearings: Journal bearings
Applications:
Utility-scale power plants
Industrial steam power generation
Combined cycle power plants
Large-scale energy projects
What Products Would This Be Used For?
High-capacity electricity generation
Base load and peak load power plants
Industrial steam and power solutions
Grid-connected energy projects
450MW generator, Steam Turbine, Steam turbine generator, Unused generator
Manufacturer | Hitachi |
Model | TC4F-26 |
Category | Generators |
Subcategory | Steam Turbine |
We pay "Top Dollar" for your idle process equipment! Fill out our form and our buying team will get back to you.
SELL YOUR EQUIPMENTView our entire process equipment inventory online or visit our location for an equipment inspection.
View Inventory