Unused- Marley Cooling Tower, NC Class

Stock# 50887001

Unused- Marley Cooling Tower, NC Class, Model NC8403RAN. Factory Assembled 2 Cell Crossflow Cooling Tower, approximately 196-482 Tons, 2100 gpm, 95 degrees F Hot Water, 85 degrees F Cold Water. 78 degrees F Entering WB, Nema 25 hp 1 speed/1 wind, 3 phase/60 Hz/230/460v, 1.15sf/TEFC. 1800 rpm. Mfg. 2020.

Unused- Marley Cooling Tower; NC Class

Stock# 50887002

Unused- Marley Cooling Tower, NC Class, Model NC8403RAN factory assembled 2 Cell Crossflow Cooling Tower, approximately 196-482 Tons, 2100 gpm; 95 degrees F Hot Water; 85 degrees F Cold Water; 78 degrees F Entering WB; Nema 25 HP 1 speed/1 wind; 3 phase/60 Hz/230/460v; 1.15sf/TEFC; 1800 rpm. Mfg. 2020.

Used- Marley, Model NC9265GM Cooling Tower.

Stock# 10151235

Used- Marley, Model NC9265GM Cooling Tower. 2366 ton capacity. Rated 7100 GPM, with 75 HP motor and gearbox.

Used- Custom Made 300 Ton Cooling Tower

Stock# 50991004

Used- Custom Made 30 ton Cooling Tower. Evaporative water cooling skid. Provides 100 kW of cooling capacity. Turnkey skid that includes chemical dosing pumps, a controller, an automatic temperature regulating mechanism, and robust process pump that provides water at 35 PSIG at 90+ GPM. Includes process pump, Chemical feed pumps, more info...

Used- BAC 2-Cell Cooling Tower, Model 15425-2

Stock# 47344003

Used- BAC 2-Cell Cooling Tower, Model 15425-2. Galvanized Steel, built for 1,083 gpm per cell or 361 nominal tons so the hot water distribution basin nozzles were selected for this flow rate. Nominal 425 ton cells or suitable for 1,275 gpm 95F to 85F at 78F w.b. entering air temperature. Includes: bottom equalizer connection, fl more info...

Used- BAC 2-Cell Cooling Tower, Model 15425-2

Stock# 47344001

Used- BAC 2-Cell Cooling Tower, Model 15425-2. Galvanized Steel, built for 1,083 gpm per cell or 361 nominal tons so the hot water distribution basin nozzles were selected for this flow rate. Nominal 425 ton cells or suitable for 1,275 gpm 95F to 85F at 78F w.b. entering air temperature. Includes: bottom equalizer connection, fl more info...

Used- SPX Cooling Technologies / Marley Counterflow Cooling Tower

Stock# 10992037

Used- SPX Cooling Technologies / Marley Counterflow Cooling Tower. Model MD5016SAF2LCBF. Designed to Serve Air Conditioning and Refrigeration Systems as Well as Light to Medium Industrial Process Loads on Clean Water. (2) Cell System. 460 Nominal Tons Capacity Based Upon 95 Degrees F HW, 85 Degrees F CW, 78 Degrees F WB and 3 GP more info...

Used- BAC Cooling Tower, Model VTI-680-PMC.

Stock# 10151234

Used- BAC Cooling Tower, Model VTI-680-PMC. Certified capacity, 680 Tons,1750 USGPM of water from 95 degree F to 85 degree F at 78 degree F entering wet bulb and 0.9 PSIG spray pressure. 2 qty. 25 hp, 1800 rpm, 3 phase, 60 hz, 230/460 suit voltz, standard TEFC enclosure. Fan drives based on 0" esp. Built 1992.

Unused - BAC Counterflow, Blow-Through Design Cooling Tower

Stock# 51756001

Unused - BAC Counterflow, Blow-Through Design Cooling Tower, Model VT1-830-S JLK, Built 2000. 830 Nominal Ton, 304 Stainless Steel Panels and Structural Members Construction. 2000 USGPM of Water from 100 Degrees F to 85 Degrees F at 78 Degrees F Entering Wet Bulb and .76 Spray Pressure. Fan Motors: (2) 75 HP, 1800 RPM, 3 Phase, more info...

Unused - BAC Counterflow, Blow-Through Design Cooling Tower

Stock# 51756002

Unused - BAC Counterflow, Blow-Through Design Cooling Tower, Model VT1-830-S JLK, Built 2000. 830 Nominal Ton, 304 Stainless Steel Panels and Structural Members Construction. 2000 USGPM of Water from 100 Degrees F to 85 Degrees F at 78 Degrees F Entering Wet Bulb and .76 Spray Pressure. Fan Motors: (2) 75 HP, 1800 RPM, 3 Phase, more info...

Used- Baltimore Aircoil Single Cell Cooling Tower

Stock# 47488002

Used- Baltimore Aircoil Single Cell Cooling Tower. Open Loop, Approximate 93 Nominal Tons, Model 2412C. Galvanized steel housing, top fan. Serial # 79-1629D. Includes a 1.5 hp Goulds pump.

Unused- Marley Cooling Tower, NC Class

Unused- Marley Cooling Tower, NC Class

Stock# 50887001

Unused- Marley Cooling Tower, NC Class, Model NC8403RAN. Factory Assembled 2 Cell Crossflow Cooling Tower, approximately 196-482 Tons, 2100 gpm, 95 degrees F Hot Water, 85 degrees F Cold Water. 78 degrees F Entering WB, Nema 25 hp 1 speed/1 wind, 3 phase/60 Hz/230/460v, 1.15sf/TEFC. 1800 rpm. Mfg. 2020.

Tons: 196-482 Mfr: Marley Model: NC8403RAN
VIEW ITEM ADD TO CART

Unused- Marley Cooling Tower; NC Class

Unused- Marley Cooling Tower; NC Class

Stock# 50887002

Unused- Marley Cooling Tower, NC Class, Model NC8403RAN factory assembled 2 Cell Crossflow Cooling Tower, approximately 196-482 Tons, 2100 gpm; 95 degrees F Hot Water; 85 degrees F Cold Water; 78 degrees F Entering WB; Nema 25 HP 1 speed/1 wind; 3 phase/60 Hz/230/460v; 1.15sf/TEFC; 1800 rpm. Mfg. 2020.

Tons: 196-482 Mfr: Marley Model: NC8403RAN
VIEW ITEM ADD TO CART

Used- Marley, Model NC9265GM Cooling Tower.

Used- Marley, Model NC9265GM Cooling Tower.

Stock# 10151235

Used- Marley, Model NC9265GM Cooling Tower. 2366 ton capacity. Rated 7100 GPM, with 75 HP motor and gearbox.

Tons: 2,366 Mfr: Marley Model: NC9265GM
VIEW ITEM ADD TO CART

Used- Custom Made 300 Ton Cooling Tower

Used- Custom Made 300 Ton Cooling Tower

Stock# 50991004

Used- Custom Made 30 ton Cooling Tower. Evaporative water cooling skid. Provides 100 kW of cooling capacity. Turnkey skid that includes chemical dosing pumps, a controller, an automatic temperature regulating mechanism, and robust process pump that provides water at 35 PSIG at 90+ GPM. Includes process pump, Chemical feed pumps, and automatic water makeup valve. Thermostat controlled water temperature. Painted steel frame. Requirements 15A of 480V/3PH electricity. Last used in a Cannabis application.

Tons: 30 Mfr: Custom Made Model:
VIEW ITEM ADD TO CART

Used- BAC 2-Cell Cooling Tower, Model 15425-2

Used- BAC 2-Cell Cooling Tower, Model 15425-2

Stock# 47344003

Used- BAC 2-Cell Cooling Tower, Model 15425-2. Galvanized Steel, built for 1,083 gpm per cell or 361 nominal tons so the hot water distribution basin nozzles were selected for this flow rate. Nominal 425 ton cells or suitable for 1,275 gpm 95F to 85F at 78F w.b. entering air temperature. Includes: bottom equalizer connection, flume box equalizer connections for equalization of the two cold water basins.

Tons: 361 Mfr: BAC Model: 15425-2
VIEW ITEM ADD TO CART

Used- BAC 2-Cell Cooling Tower, Model 15425-2

Used- BAC 2-Cell Cooling Tower, Model 15425-2

Stock# 47344001

Used- BAC 2-Cell Cooling Tower, Model 15425-2. Galvanized Steel, built for 1,083 gpm per cell or 361 nominal tons so the hot water distribution basin nozzles were selected for this flow rate. Nominal 425 ton cells or suitable for 1,275 gpm 95F to 85F at 78F w.b. entering air temperature. Includes: bottom equalizer connection, flume box equalizer connections for equalization of the two cold water basins.

Tons: 425 Mfr: BAC Model: 15425-2
VIEW ITEM ADD TO CART

Used- SPX Cooling Technologies / Marley Counterflow Cooling Tower

Used- SPX Cooling Technologies / Marley Counterflow Cooling Tower

Stock# 10992037

Used- SPX Cooling Technologies / Marley Counterflow Cooling Tower. Model MD5016SAF2LCBF. Designed to Serve Air Conditioning and Refrigeration Systems as Well as Light to Medium Industrial Process Loads on Clean Water. (2) Cell System. 460 Nominal Tons Capacity Based Upon 95 Degrees F HW, 85 Degrees F CW, 78 Degrees F WB and 3 GPM/Ton Per Cell. Nominal Cell Size 12' x 12'.

Tons: 460 Mfr: SPX Model: MD5016SAF2LCBF
VIEW ITEM ADD TO CART

Used- BAC Cooling Tower, Model VTI-680-PMC.

Used- BAC Cooling Tower, Model VTI-680-PMC.

Stock# 10151234

Used- BAC Cooling Tower, Model VTI-680-PMC. Certified capacity, 680 Tons,1750 USGPM of water from 95 degree F to 85 degree F at 78 degree F entering wet bulb and 0.9 PSIG spray pressure. 2 qty. 25 hp, 1800 rpm, 3 phase, 60 hz, 230/460 suit voltz, standard TEFC enclosure. Fan drives based on 0" esp. Built 1992.

Tons: 680 Mfr: BAC Model: VTI-680-PMC
VIEW ITEM ADD TO CART

Unused - BAC Counterflow, Blow-Through Design Cooling Tower

Unused - BAC Counterflow, Blow-Through Design Cooling Tower

Stock# 51756001

Unused - BAC Counterflow, Blow-Through Design Cooling Tower, Model VT1-830-S JLK, Built 2000. 830 Nominal Ton, 304 Stainless Steel Panels and Structural Members Construction. 2000 USGPM of Water from 100 Degrees F to 85 Degrees F at 78 Degrees F Entering Wet Bulb and .76 Spray Pressure. Fan Motors: (2) 75 HP, 1800 RPM, 3 Phase, 60 Hertz, Suit 460 Volts, Inverter Duty; Premium Efficient TEFC; Enclosure. Fan Drives Based on 0" ESP.Inverter Duty Fan Motors, Furnished in Accordance with NEMA Standard MG.1 Part 31 are Required for Applications using Variable Frequency Drives for Fan Motor Control; Stainless Steel Eliminators; Fan Wheels Finished with Baltibond Corrosion Protection System; FM Approved Wet Deck; Watertight Baffle for Independent Cell Operation; Full Stainless Steel Sound Attenuation with Solid Bottom Panels; Extended Lubrication Lines and Air Inlet Screens; Vibration Isolation Rails; Vibration Cutout Switch(es); (2) Aluminum Ladders and Steel Safety Cages with 3' Extensions; (2) Electric Heater Packages with (1) 8kw Heater Element; 8" Equalizer and Bypass Connections on Blankoff Panel Bottom Outlet. Tower Consists of (4) Pieces; (1) Bottom Stainless Steel BAse, (2) Top Cell Stainless Steel, (1) Bottom Sound Attenuator Inlet Casing. Overall Dimensions: 24'-0 1/2"W x 11'-10'D x 20'-1 5/8"H (w/o Ladder), Approximate Shipping Weight: 26,520 lbs. Does not include the following: Lower Basin Access Doors; External Service Access Door Platform, Guardrails, Ladders; Power and Control Wiring; Tower Base Rail Supports and Spring Isolators.

Tons: 830 Mfr: BAC Model: VT1-830-S JLK
VIEW ITEM ADD TO CART

Unused - BAC Counterflow, Blow-Through Design Cooling Tower

Unused - BAC Counterflow, Blow-Through Design Cooling Tower

Stock# 51756002

Unused - BAC Counterflow, Blow-Through Design Cooling Tower, Model VT1-830-S JLK, Built 2000. 830 Nominal Ton, 304 Stainless Steel Panels and Structural Members Construction. 2000 USGPM of Water from 100 Degrees F to 85 Degrees F at 78 Degrees F Entering Wet Bulb and .76 Spray Pressure. Fan Motors: (2) 75 HP, 1800 RPM, 3 Phase, 60 Hertz, Suit 460 Volts, Inverter Duty; Premium Efficient TEFC; Enclosure. Fan Drives Based on 0" ESP.Inverter Duty Fan Motors, Furnished in Accordance with NEMA Standard MG.1 Part 31 are Required for Applications using Variable Frequency Drives for Fan Motor Control; Stainless Steel Eliminators; Fan Wheels Finished with Baltibond Corrosion Protection System; FM Approved Wet Deck; Watertight Baffle for Independent Cell Operation; Full Stainless Steel Sound Attenuation with Solid Bottom Panels; Extended Lubrication Lines and Air Inlet Screens; Vibration Isolation Rails; Vibration Cutout Switch(es); (2) Aluminum Ladders and Steel Safety Cages with 3' Extensions; (2) Electric Heater Packages with (1) 8kw Heater Element; 8" Equalizer and Bypass Connections on Blankoff Panel Bottom Outlet. Tower Consists of (4) Pieces; (1) Bottom Stainless Steel BAse, (2) Top Cell Stainless Steel, (1) Bottom Sound Attenuator Inlet Casing. Overall Dimensions: 24'-0 1/2"W x 11'-10'D x 20'-1 5/8"H (w/o Ladder), Approximate Shipping Weight: 26,520 lbs. Does not include the following: Lower Basin Access Doors; External Service Access Door Platform, Guardrails, Ladders; Power and Control Wiring; Tower Base Rail Supports and Spring Isolators.

Tons: 830 Mfr: BAC Model: VT1-830-S JLK
VIEW ITEM ADD TO CART

Used- Baltimore Aircoil Single Cell Cooling Tower

Used- Baltimore Aircoil Single Cell Cooling Tower

Stock# 47488002

Used- Baltimore Aircoil Single Cell Cooling Tower. Open Loop, Approximate 93 Nominal Tons, Model 2412C. Galvanized steel housing, top fan. Serial # 79-1629D. Includes a 1.5 hp Goulds pump.

Tons: 93 Mfr: BAC Model: 2412C
VIEW ITEM ADD TO CART
  • Unused- Marley Cooling Tower, NC Class

    Unused- Marley Cooling Tower, NC Class, Model NC8403RAN. Factory Assembled 2 Cell Crossflow Cooling Tower, approximately 196-482 Tons, 2100 gpm, 95 degrees F Hot Water, 85 degrees F Cold Water. 78 degrees F Entering WB, Nema 25 hp 1 speed/1 wind, 3 phase/60 Hz/230/460v, 1.15sf/TEFC. 1800 rpm. Mfg. 2020.

    VIEW ITEM
  • Unused- Marley Cooling Tower; NC Class

    Unused- Marley Cooling Tower, NC Class, Model NC8403RAN factory assembled 2 Cell Crossflow Cooling Tower, approximately 196-482 Tons, 2100 gpm; 95 degrees F Hot Water; 85 degrees F Cold Water; 78 degrees F Entering WB; Nema 25 HP 1 speed/1 wind; 3 phase/60 Hz/230/460v; 1.15sf/TEFC; 1800 rpm. Mfg. 2020.

    VIEW ITEM
  • Used- Marley, Model NC9265GM Cooling Tower.

    Used- Marley, Model NC9265GM Cooling Tower. 2366 ton capacity. Rated 7100 GPM, with 75 HP motor and gearbox.

    VIEW ITEM
  • Used- Custom Made 300 Ton Cooling Tower

    Used- Custom Made 30 ton Cooling Tower. Evaporative water cooling skid. Provides 100 kW of cooling capacity. Turnkey skid that includes chemical dosing pumps, a controller, an automatic temperature regulating mechanism, and robust process pump that provides water at 35 PSIG at 90+ GPM. Includes process pump, Chemical feed pumps, and automatic water makeup valve. Thermostat controlled water temperature. Painted steel frame. Requirements 15A of 480V/3PH electricity. Last used in a Cannabis application.

    VIEW ITEM
  • Used- BAC 2-Cell Cooling Tower, Model 15425-2

    Used- BAC 2-Cell Cooling Tower, Model 15425-2. Galvanized Steel, built for 1,083 gpm per cell or 361 nominal tons so the hot water distribution basin nozzles were selected for this flow rate. Nominal 425 ton cells or suitable for 1,275 gpm 95F to 85F at 78F w.b. entering air temperature. Includes: bottom equalizer connection, flume box equalizer connections for equalization of the two cold water basins.

    VIEW ITEM
  • Used- BAC 2-Cell Cooling Tower, Model 15425-2

    Used- BAC 2-Cell Cooling Tower, Model 15425-2. Galvanized Steel, built for 1,083 gpm per cell or 361 nominal tons so the hot water distribution basin nozzles were selected for this flow rate. Nominal 425 ton cells or suitable for 1,275 gpm 95F to 85F at 78F w.b. entering air temperature. Includes: bottom equalizer connection, flume box equalizer connections for equalization of the two cold water basins.

    VIEW ITEM
  • Used- SPX Cooling Technologies / Marley Counterflow Cooling Tower

    Used- SPX Cooling Technologies / Marley Counterflow Cooling Tower. Model MD5016SAF2LCBF. Designed to Serve Air Conditioning and Refrigeration Systems as Well as Light to Medium Industrial Process Loads on Clean Water. (2) Cell System. 460 Nominal Tons Capacity Based Upon 95 Degrees F HW, 85 Degrees F CW, 78 Degrees F WB and 3 GPM/Ton Per Cell. Nominal Cell Size 12' x 12'.

    VIEW ITEM
  • Used- BAC Cooling Tower, Model VTI-680-PMC.

    Used- BAC Cooling Tower, Model VTI-680-PMC. Certified capacity, 680 Tons,1750 USGPM of water from 95 degree F to 85 degree F at 78 degree F entering wet bulb and 0.9 PSIG spray pressure. 2 qty. 25 hp, 1800 rpm, 3 phase, 60 hz, 230/460 suit voltz, standard TEFC enclosure. Fan drives based on 0" esp. Built 1992.

    VIEW ITEM
  • Unused - BAC Counterflow, Blow-Through Design Cooling Tower

    Unused - BAC Counterflow, Blow-Through Design Cooling Tower, Model VT1-830-S JLK, Built 2000. 830 Nominal Ton, 304 Stainless Steel Panels and Structural Members Construction. 2000 USGPM of Water from 100 Degrees F to 85 Degrees F at 78 Degrees F Entering Wet Bulb and .76 Spray Pressure. Fan Motors: (2) 75 HP, 1800 RPM, 3 Phase, 60 Hertz, Suit 460 Volts, Inverter Duty; Premium Efficient TEFC; Enclosure. Fan Drives Based on 0" ESP.Inverter Duty Fan Motors, Furnished in Accordance with NEMA Standard MG.1 Part 31 are Required for Applications using Variable Frequency Drives for Fan Motor Control; Stainless Steel Eliminators; Fan Wheels Finished with Baltibond Corrosion Protection System; FM Approved Wet Deck; Watertight Baffle for Independent Cell Operation; Full Stainless Steel Sound Attenuation with Solid Bottom Panels; Extended Lubrication Lines and Air Inlet Screens; Vibration Isolation Rails; Vibration Cutout Switch(es); (2) Aluminum Ladders and Steel Safety Cages with 3' Extensions; (2) Electric Heater Packages with (1) 8kw Heater Element; 8" Equalizer and Bypass Connections on Blankoff Panel Bottom Outlet. Tower Consists of (4) Pieces; (1) Bottom Stainless Steel BAse, (2) Top Cell Stainless Steel, (1) Bottom Sound Attenuator Inlet Casing. Overall Dimensions: 24'-0 1/2"W x 11'-10'D x 20'-1 5/8"H (w/o Ladder), Approximate Shipping Weight: 26,520 lbs. Does not include the following: Lower Basin Access Doors; External Service Access Door Platform, Guardrails, Ladders; Power and Control Wiring; Tower Base Rail Supports and Spring Isolators.

    VIEW ITEM
  • Unused - BAC Counterflow, Blow-Through Design Cooling Tower

    Unused - BAC Counterflow, Blow-Through Design Cooling Tower, Model VT1-830-S JLK, Built 2000. 830 Nominal Ton, 304 Stainless Steel Panels and Structural Members Construction. 2000 USGPM of Water from 100 Degrees F to 85 Degrees F at 78 Degrees F Entering Wet Bulb and .76 Spray Pressure. Fan Motors: (2) 75 HP, 1800 RPM, 3 Phase, 60 Hertz, Suit 460 Volts, Inverter Duty; Premium Efficient TEFC; Enclosure. Fan Drives Based on 0" ESP.Inverter Duty Fan Motors, Furnished in Accordance with NEMA Standard MG.1 Part 31 are Required for Applications using Variable Frequency Drives for Fan Motor Control; Stainless Steel Eliminators; Fan Wheels Finished with Baltibond Corrosion Protection System; FM Approved Wet Deck; Watertight Baffle for Independent Cell Operation; Full Stainless Steel Sound Attenuation with Solid Bottom Panels; Extended Lubrication Lines and Air Inlet Screens; Vibration Isolation Rails; Vibration Cutout Switch(es); (2) Aluminum Ladders and Steel Safety Cages with 3' Extensions; (2) Electric Heater Packages with (1) 8kw Heater Element; 8" Equalizer and Bypass Connections on Blankoff Panel Bottom Outlet. Tower Consists of (4) Pieces; (1) Bottom Stainless Steel BAse, (2) Top Cell Stainless Steel, (1) Bottom Sound Attenuator Inlet Casing. Overall Dimensions: 24'-0 1/2"W x 11'-10'D x 20'-1 5/8"H (w/o Ladder), Approximate Shipping Weight: 26,520 lbs. Does not include the following: Lower Basin Access Doors; External Service Access Door Platform, Guardrails, Ladders; Power and Control Wiring; Tower Base Rail Supports and Spring Isolators.

    VIEW ITEM
  • Used- Baltimore Aircoil Single Cell Cooling Tower

    Used- Baltimore Aircoil Single Cell Cooling Tower. Open Loop, Approximate 93 Nominal Tons, Model 2412C. Galvanized steel housing, top fan. Serial # 79-1629D. Includes a 1.5 hp Goulds pump.

    VIEW ITEM
Cash Icon
Surplus Equipment?

We pay "Top Dollar" for your idle process equipment! Fill out our form and our buying team will get back to you.

SELL YOUR EQUIPMENT
Search Icon
Browse Inventory

View our entire process equipment inventory online or visit our location for an equipment inspection.

View Inventory
Phone Icon
Contact Us

Email or call us to speak with an equipment specialist to answer any machinery questions you may have.

630-350-2200