Adhesive and Sealant Equipment
Stock No.:
54541006Unused 900 kW MTU Diesel Generator with Sound Attenuated Enclosure & Digital Controls
Unused 900 kW MTU Diesel Generator with Sound Attenuated Enclosure & Digital Controls. Rated 900 kW/1125 kV. MTU 22.4L Diesel Engine, 1800 RPM, EPA Tier 2 Certified for Emergency Standby. Permanent Magnet Generator Alternator with Digital Voltage Regulator & Generator Strip Heater. Sound Level 3 Enclosure with Vertical Air Discharge, Steel Construction, 130 MPH Wind Load Rated, 74.9 dBA, Space Heater, Motorized Intake Louvers. Internally Mounted Silencer within Enclosure, Critical Grade. MGC-3050 Digital Control Panel, Mounted Left Side, Paralleling Capabilities. ModBus TCP/IP Communications. Remote Mounted Annunciator, Meets NFPA 110 Level 1. Remote Mounted Emergency Stop, Break Glass Station, Nema 3R For Outdoor Installation. 1200 Amp Breaker, 3-Pole, 100% Rated with Electronic LSI Trip, Mounted Right Side, Motor Operated Block. 5000W, 1ph, 208V Heater. 10 Amp, 24VDC / 120VAC 1ph Battery Charger. NFPA-110 Level 1 Compliance, UL2200 Listed Fuel Tank: 1515 Gallon, 24 Hour Run Time at Full Load, UL 142 Listed. Built 2024.
MFR: MTU Onsite Energy
Stock No.:
54541007MTU Rolls-Royce 900 kW Standby Generator – Tier 2 Diesel Engine – Unused 2024
MTU Rolls-Royce 900 kW Standby Generator Tier 2 Diesel Engine Unused 2024. Rated 900 kW/1125 kV. MTU 22.4L Diesel Engine, 1800 RPM, EPA Tier 2 Certified for Emergency Standby. Permanent Magnet Generator Alternator with Digital Voltage Regulator & Generator Strip Heater. Sound Level 3 Enclosure with Vertical Air Discharge, Steel Construction, 130 MPH Wind Load Rated, 74.9 dBA, Space Heater, Motorized Intake Louvers. Internally Mounted Silencer within Enclosure, Critical Grade. MGC-3050 Digital Control Panel, Mounted Left Side, Paralleling Capabilities. ModBus TCP/IP Communications. Remote Mounted Annunciator, Meets NFPA 110 Level 1. Remote Mounted Emergency Stop, Break Glass Station, Nema 3R For Outdoor Installation. 1200 Amp Breaker, 3-Pole, 100% Rated with Electronic LSI Trip, Mounted Right Side, Motor Operated Block. 5000W, 1ph, 208V Heater. 10 Amp, 24VDC / 120VAC 1ph Battery Charger. NFPA-110 Level 1 Compliance, UL2200 Listed Fuel Tank: 1515 Gallon, 24 Hour Run Time at Full Load, UL 142 Listed. Built 2024.
MFR: MTU Onsite Energy
Stock No.:
545410082024 MTU Rolls-Royce DS900 900 kW Diesel Generator Set – UL2200 Listed & NFPA 110 Level 1
Unused- 2024 MTU Rolls-Royce DS900 900 kW Diesel Generator Set UL2200 Listed & NFPA 110 Level 1. Rated 900 kW/1125 kV. MTU 22.4L Diesel Engine, 1800 RPM, EPA Tier 2 Certified for Emergency Standby. Permanent Magnet Generator Alternator with Digital Voltage Regulator & Generator Strip Heater. Sound Level 3 Enclosure with Vertical Air Discharge, Steel Construction, 130 MPH Wind Load Rated, 74.9 dBA, Space Heater, Motorized Intake Louvers. Internally Mounted Silencer within Enclosure, Critical Grade. MGC-3050 Digital Control Panel, Mounted Left Side, Paralleling Capabilities. ModBus TCP/IP Communications. Remote Mounted Annunciator, Meets NFPA 110 Level 1. Remote Mounted Emergency Stop, Break Glass Station, Nema 3R For Outdoor Installation. 1200 Amp Breaker, 3-Pole, 100% Rated with Electronic LSI Trip, Mounted Right Side, Motor Operated Block. 5000W, 1ph, 208V Heater. 10 Amp, 24VDC / 120VAC 1ph Battery Charger. NFPA-110 Level 1 Compliance, UL2200 Listed Fuel Tank: 1515 Gallon, 24 Hour Run Time at Full Load, UL 142 Listed. Built 2024.
MFR: MTU Onsite Energy
Stock No.:
54541009Unused MTU Rolls-Royce DS900 900 kW Emergency Standby Diesel Generator with 1,515 Gallon Fuel Tank
Unused MTU Rolls-Royce DS900 900 kW Emergency Standby Diesel Generator with 1,515 Gallon Fuel Tank. Rated 900 kW/1125 kV. MTU 22.4L Diesel Engine, 1800 RPM, EPA Tier 2 Certified for Emergency Standby. Permanent Magnet Generator Alternator with Digital Voltage Regulator & Generator Strip Heater. Sound Level 3 Enclosure with Vertical Air Discharge, Steel Construction, 130 MPH Wind Load Rated, 74.9 dBA, Space Heater, Motorized Intake Louvers. Internally Mounted Silencer within Enclosure, Critical Grade. MGC-3050 Digital Control Panel, Mounted Left Side, Paralleling Capabilities. ModBus TCP/IP Communications. Remote Mounted Annunciator, Meets NFPA 110 Level 1. Remote Mounted Emergency Stop, Break Glass Station, Nema 3R For Outdoor Installation. 1200 Amp Breaker, 3-Pole, 100% Rated with Electronic LSI Trip, Mounted Right Side, Motor Operated Block. 5000W, 1ph, 208V Heater. 10 Amp, 24VDC / 120VAC 1ph Battery Charger. NFPA-110 Level 1 Compliance, UL2200 Listed Fuel Tank: 1515 Gallon, 24 Hour Run Time at Full Load, UL 142 Listed. Built 2024.
MFR: MTU Onsite Energy
Stock No.:
53767003Used 9,000 Gallon 316 SS Vertical Agitated Reactor | Half-Pipe Jacket | Full Vacuum | Internal Coil | Industrial Alloy Fabricators
Used 9,000 Gallon 316 SS Vertical Agitated Reactor | Half-Pipe Jacket | Full Vacuum | Internal Coil | Industrial Alloy Fabricators. Approx. 108" D x approx. 259" straight side. 6" D bottom outlet. Flat top and bottom. 15 PSI internal pressure. 300 degrees F internal temp. 50 PSI jacket pressure. 300 degrees F jacket temp. Half pipe/limpet jacket type. Full vacuum internal. 304 stainless steel jacket. Has internal coil. Has (4) sidewall mounted, full-length straight baffles. Wide sweep impeller. Two-tier, (3) blade agitator. 2.5 HP, 37 RPM drive. 1.5HP, 1155 RPM motor. NB 2033. Mounted on skirt. Built 1992.
MFR: Industrial Alloy Fab
Stock No.:
53767005Used 9,000 Gallon 316 Stainless Steel Jacketed Reactor with Internal Coil & Agitation | Industrial Alloy Fabricators
Used 9,000 Gallon 316 Stainless Steel Jacketed Reactor with Internal Coil & Agitation | Industrial Alloy Fabricators. Stainless Steel 316. Approx. 108" D x approx. 259" straight side. 6" D bottom outlet. Dish top and bottom. 15 PSI internal pressure. 300 degrees F internal temp. 50 PSI jacket pressure. 300 degrees F jacket temp. Half pipe/limpet jacket type. Full vacuum internal. 304 stainless steel jacket. Has internal coil. Has (4) sidewall mounted, full-length straight baffles. Wide sweep impeller. Two-tier, (3) blade agitator. 2.5 HP, 37 RPM drive. 1.5HP, 1155 RPM motor. NB 2032. Mounted on skirt. Built 1992.
MFR: Industrial Alloy Fab
Stock No.:
54344001Used M.L. Smith Jr. 9,000 Gallon 316L Stainless Steel Vertical Tank – 8' x 24', 200°F Rated
Used- M.L Smith Jr. 316L Stainless Steel Vertical Tank, 9,000 Gallon. 96" diameter x 288" straight side. 3/16" thick walls. Atmospheric at 200 degrees F. Slight cone top, flat bottom. Openings Top: 6", 3". (2) 24" diameter side manways, 3" side bottom outlet with 6" discharge height. Serial# 0298. Built 2006.
Stock No.:
53485001Used APV (Tetra Pak) Plate Heat Exchanger – Model N35, 908 Sq. Ft., 10 Bar
Used- APV (Tetra Pak) Plate Heat Exchanger, Model N35. 84.4 m2 / 908 Square Feet. 10 bar (145 psi). 0 - 95 degrees c (32 - 203 degrees F.). Qty (300) plus Plates. Control panel with A/B panelview plus 600 HMI. Mounted on expandable frame.
MFR: TetraPak
Stock No.:
14191139Unused 9,100-Gallon 304L Stainless Steel Reactor by Borghi Srl
Unused 304L Stainless Steel Reactor, 9100 Gallon Capacity. Manufactured by Borghi Srl. 8200 gallon working capacity. Internal MAWP 87 psi @ 400F. Halfpipe jacket MAWP 174 psi @ 400F. Half pipe jacketed on bottom half of shell and bottom head. Sanitary polished internal and exterior top shell. Dome top and bottom with 2" Center bottom outlet. Top flange and (4) internal baffles with vortex breaker. (4) Lug mounted. Does not include motor and agitator. 20" top manway. Diameter 9.84 ft x height 19.03 ft. Weight 21,605 lb. National Board and PED (Double certification). Serial #PP052B, NB #5. Built 2025. Our freight specialists can assist you with door to door transportation and all customs documents needed to make the process go as smoothly as possible.
Stock No.:
50420004Ellett Industries Shell & Tube Heat Exchanger. Used.
Used- Ellett Industries Shell & Tube Heat Exchanger, 930 Square Foot. Horizontal. Single pass. (237) Zirconium (SB-523) 3/4" diameter x 20' long tubes rated 165 psi / FV at -20 to 550 degrees F. 304L Stainless steel shell rated 75 psi at -20 to 200 degrees F. Openings shell: (2) 8", tubes: (2) 8". Saddle mounted. National Board # 719. Serial # 43890. Built 2008. Previous use Nitric Acid cooler condenser.
MFR: Ellet Mfg
Stock No.:
10151608Used Ziemann Bauer 9,300 Gallon Jacketed Pressure Vessel | 300 BBL Stainless Steel Fermentation Tank
Used Ziemann Bauer GmbH 9,300 gallon (300 BBL) 304 stainless steel jacketed pressure vessel. Vertical vessel measures 10' 2" diameter x 30' tall with dished head and cone bottom. Vessel rated 29 psi at 86 F; jacket rated 43 psi at 86 F and cooled with glycol at 24 F. Previously used for brewery fermentation. National Board # 145, Serial # 8623-14300129/1000, Built 2012. Possible applications include brewery fermentation and temperature-controlled beverage processing for beer, cider, kombucha, hard seltzer, wine and similar liquid products.