Your Files Are Being Processed
Please Wait
Contact Information
Phone: 630-350-2200
Toll Free: 1-800-49-AARON
Email: websales@aaronequipment.com
Used On Site Gas Systems PSA Pressure Swing Adsorption Nitrogen Generator, Model N-200, Serial #3224, built 2005. Producing 1,519 SCFH at 99.9% purity, plus (2) additional purity options, 99.95% and 99.99%. Unit includes (2) West Warwick Welding adsorber pressure tanks, rated 200 psi at 250 degrees F, National Board #7274, 7275. Base mounted, 20063 hours on meter. (1) Silvan air receiver pressure tank, approximately 500 gallons, rated 200 psi at 450 degree, National Board #454751. (1) Manchester product receiver tank, approximately 660 gallons, rated 137 psi at 450 degrees F, National Board #104306; (1) Silvan receiver pressure tank, approximately 227 gallons, rated 400 psi at 450 degree, National Board #461444; (1) Manchester product receiver tank, approximately 60 gallons, rated 200 psi at 650 degrees F, National Board #99803. (1) On Site Gas Systems O2 Analyzer, Model 1100, and (1) Hycomp oil free booster compressor, model AN10C-B21-ANMV-20/10D, serial #050420-502. Driven by a 10 hp, 3/60/208-230/460 volt, 1760 rpm motor. Designed to bring the nitrogen pressure up to about 250 psig to the laser nozzle. Includes a control panel, base mounted, 10556 hours on meter.
Used On Site Gas Systems PSA Pressure Swing Adsorption Nitrogen Generator, Model N-200, Serial #3224, built 2005. Producing 1,519 SCFH at 99.9% purity, plus (2) additional purity options, 99.95% and 99.99%. Unit includes (2) West Warwick Welding adsorber pressure tanks, rated 200 psi at 250 degrees F, National Board #7274, 7275. Base mounted, 20063 hours on meter. (1) Silvan air receiver pressure tank, approximately 500 gallons, rated 200 psi at 450 degree, National Board #454751. (1) Manchester product receiver tank, approximately 660 gallons, rated 137 psi at 450 degrees F, National Board #104306; (1) Silvan receiver pressure tank, approximately 227 gallons, rated 400 psi at 450 degree, National Board #461444; (1) Manchester product receiver tank, approximately 60 gallons, rated 200 psi at 650 degrees F, National Board #99803. (1) On Site Gas Systems O2 Analyzer, Model 1100, and (1) Hycomp oil free booster compressor, model AN10C-B21-ANMV-20/10D, serial #050420-502. Driven by a 10 hp, 3/60/208-230/460 volt, 1760 rpm motor. Designed to bring the nitrogen pressure up to about 250 psig to the laser nozzle. Includes a control panel, base mounted, 10556 hours on meter.
We pay "Top Dollar" for your idle process equipment! Fill out our form and our buying team will get back to you.
SELL YOUR EQUIPMENTView our entire process equipment inventory online or visit our location for an equipment inspection.
View Inventory