Used Cleaver Brooks 250 HP, Model CBLE 700-250-125, 4-Pass Dryback Firetube Boiler. Hydronic heating firetube boiler is designed at 125 psig pressure, natural gas. Built in 2010. Fuel consumption - natural gas- 10,460 SCFH at 3-10 psig. 480 VAC, 3/60 50 amps. Includes- FD fan with 10 hp motor and fused starter. Low NOx natural gas firing. CB7800 burner management system with expanded annunciator. Honeywell UDC2500 controller. Servo motor parallel positioning combustion control. NEMA 12 Panel. 480v -115v control voltage transformer. Dual low water cut offs. Pressure and temperature gauges. Safety relief valves. Drain valves. Meets FM/IRI insurance, CSD-1 and California code requirements. Bell and Gossett size 1510 circulating pump, base mounted and connected to a 10 hp TEFC, 1800 rpm motor. Shipped loose and rated at 800 gpm at 30 TDH. Operating and maintenance manuals with drawings. Connection sizes - hot water supply- 8" 105 lb. flange, hot water return, 8" 125 lb. flange, 2" NPT for natural gas and 2" NPT for drain. Emissions data (natural gas):NOx (corr. to 3% O2): 30 ppm. CO (corr. to 3% O2): 50 ppm.
Used Cleaver Brooks 250 HP, Model CBLE 700-250-125, 4-Pass Dryback Firetube Boiler. Hydronic heating firetube boiler is designed at 125 psig pressure, natural gas. Built in 2010. Fuel consumption - natural gas- 10,460 SCFH at 3-10 psig. 480 VAC, 3/60 50 amps. Includes- FD fan with 10 hp motor and fused starter. Low NOx natural gas firing. CB7800 burner management system with expanded annunciator. Honeywell UDC2500 controller. Servo motor parallel positioning combustion control. NEMA 12 Panel. 480v -115v control voltage transformer. Dual low water cut offs. Pressure and temperature gauges. Safety relief valves. Drain valves. Meets FM/IRI insurance, CSD-1 and California code requirements. Bell and Gossett size 1510 circulating pump, base mounted and connected to a 10 hp TEFC, 1800 rpm motor. Shipped loose and rated at 800 gpm at 30 TDH. Operating and maintenance manuals with drawings. Connection sizes - hot water supply- 8" 105 lb. flange, hot water return, 8" 125 lb. flange, 2" NPT for natural gas and 2" NPT for drain. Emissions data (natural gas):NOx (corr. to 3% O2): 30 ppm. CO (corr. to 3% O2): 50 ppm.
We pay "Top Dollar" for your idle process equipment! Fill out our form and our buying team will get back to you.
SELL YOUR EQUIPMENTView our entire process equipment inventory online or visit our location for an equipment inspection.
View Inventory