Stock# 53907001
Used Spray Drying Plant including: Bowen 16' Spray Dryer Technical Data: Feed Rate: 3400 lbs/hr, Feed Solids: 50.0%, Feed Temperature: 50F, Evaporation Rate: 1575 lbs/hr, Powder Rate: 1800 lbs/hr, Product Moisture: 5.0%, Inlet Temperature: 430F, Outlet Temperature: 305F, Ambient Temperature: 50F, Plant Elevation: Sea-level, Fuel Consumption: 7.0 MM Btu/hr, Power Consumption: 225 kW. Includes the following: (1) Bowen 16' Spray Dryer, Spray Chamber (CH-1010), Spray Machine (SM-1011), (1) Burner (B-1000), (1) Cyclone (CY-1020), 396-7/16"H x 99" ID (D-46024), (1) Rotary Valve (RV-1021), (1) Rotary Valve Motor (M-1021), (1) Venturi (V-1033), (1) Conveying Fan (CF-1050), (1) Conveying Fan Motor (M-1050), (1) Product Cyclone (CY-1061), 128"H x 30"ID (D-46395), (1) Product Cyclone Hopper 2000 Lb. (PH-1060), (1) Rotary Valve (RV-1062), (1) Rotary Valve Motor (M-1062), (1) Screen (SC-1081), (1) Scrubber Pump (P-1032), (1) Scrubber Pump Motor (M-105), (1) Recirc Tank (L-1031), (1) Wet Scrubber (WS-1030), (1) Main Fan (F-1035), (1) Main Fan Motor (M-103), (1) Duplex Strainer (ST-1072), (1) Water Tank (T1071), (1) Flow Meter (FM-1322), (1) Feed Pump (P-1070), (1) Feed Pump Motor (M-1070), (1) Dryer to Cyclone 36" Duct Assy (D-46390), (1) Cyclone Pot Weldment (D-46025), 122-13/16"H x 69-1/2"ID, (1) Cyclone to Scrubber 36" Duct Assembly (D-46393), (1) Cyclone to Scrubber Duct, Venturi Duct (D-46396), (1) Scrubber to Fan Ductwork - GA (D-46400 & D-46401), Cyclone Explosion Relief Panel Assy (D-46440, -46441, -46442 & -46445), Spray Drying Access Platforms - Framing Plans (8', 13' & 16' Elev.) (D-46459), Spray Drying Access Platforms - Framing Plan (22'-10" Level) (D-46471), Spray Dryer Access Platform - Column & Bracing GA (D-46472 & D-46473), Spray Dryer Access Platform - Framing Plan (26'-3.75" & 28'-2" Levels) (D-46474), Spray Dryer Conveying Duct Venturi (D-46480), Spray Drying Access Platforms - Framing Plan (33'-2" Elev.) (D-46505), Spray Dryer Access Platform - Framing Plan