Used Cleaver-Brooks Skid Mounted Model CBLE 700-250-125 Hydronic Heating Hot Water Boiler. 250 hp. 8.4 mmbtu output. 125 psig pressure, firing natural gas. It was built in 2010, is fully piped and wired and includes the following components: 250 HP Cleaver Brooks 4-pass Dryback Firetube Boiler, FD Fan with 10 HP Motor & Fused Starter, Low NOx Natural Gas Firing,CB7800 Burner Management System with Expanded Annunciator, Honeywell UDC2500 Controller, Servo Motor Parallel Positioning Combustion Control, NEMA 12 Panel,480v - 115v Control Voltage Transformer, Dual Low Water Cut Offs, Pressure/Temperature Gauges, Safety Relief Valves, Drain Valves. Meets FM/IRI Insurance, CSD-1 and California Code Requirements, Bell & Gossett Size 1510 Circulating Pump, Base Mounted Connected to a 10 HP TEFC, 1800 rpm Motor - Shipped Loose (800 gpm at 30 TDH) O&M Manuals with Drawings. Fuel Consumption: Natural Gas: 10,460 SCFH at 3-10 psig. Connection Sizes: Hot Water Supply: 8"-150 # FLG, Hot Water Return: 8"-125 # FLG, Natural Gas: 2" NPT, Drain: 2" NPT. Electrical Power Service Requirements: 480 VAC, 3 ph, 60 hz, 50 AMPS. Operating Weight: 35,580 lbs. Emissions Data (natural gas): NOx (corr. to 3% O2): 30 ppm, CO (corr. to 3% O2): 50 ppm.
Used Cleaver-Brooks Skid Mounted Model CBLE 700-250-125 Hydronic Heating Hot Water Boiler. 250 hp. 8.4 mmbtu output. 125 psig pressure, firing natural gas. It was built in 2010, is fully piped and wired and includes the following components: 250 HP Cleaver Brooks 4-pass Dryback Firetube Boiler, FD Fan with 10 HP Motor & Fused Starter, Low NOx Natural Gas Firing,CB7800 Burner Management System with Expanded Annunciator, Honeywell UDC2500 Controller, Servo Motor Parallel Positioning Combustion Control, NEMA 12 Panel,480v - 115v Control Voltage Transformer, Dual Low Water Cut Offs, Pressure/Temperature Gauges, Safety Relief Valves, Drain Valves. Meets FM/IRI Insurance, CSD-1 and California Code Requirements, Bell & Gossett Size 1510 Circulating Pump, Base Mounted Connected to a 10 HP TEFC, 1800 rpm Motor - Shipped Loose (800 gpm at 30 TDH) O&M Manuals with Drawings. Fuel Consumption: Natural Gas: 10,460 SCFH at 3-10 psig. Connection Sizes: Hot Water Supply: 8"-150 # FLG, Hot Water Return: 8"-125 # FLG, Natural Gas: 2" NPT, Drain: 2" NPT. Electrical Power Service Requirements: 480 VAC, 3 ph, 60 hz, 50 AMPS. Operating Weight: 35,580 lbs. Emissions Data (natural gas): NOx (corr. to 3% O2): 30 ppm, CO (corr. to 3% O2): 50 ppm.
We pay "Top Dollar" for your idle process equipment! Fill out our form and our buying team will get back to you.
SELL YOUR EQUIPMENTView our entire process equipment inventory online or visit our location for an equipment inspection.
View Inventory