General Electric Steam Turbine-Generator. 66,086 kW rated straight condensing steam turbine and an ...

Stock# 48321001

Used- General Electric Steam Turbine-Generator. 66,086 kW rated straight condensing steam turbine and an 80,300 kVA rated generator, including its auxiliary systems and the condenser system. Condenser is a Graham water cooled condenser with a duty of 434.83 x 106 btu/lb, exhaust pressure of 2.24” HgA and turbine exhaust flow of more info...

Used- Dresser-Rand/Murray Steam Turbine, Model RD6M. 3507 kW

Stock# 47317001

Used- Dresser-Rand/Murray Steam Turbine, Model RD6M. 3507 kW of power at 5250 RPM, using 60,000 lb./hr. steam at 390 psig and 446 deg. F. With a controlled extraction of 31,900 lb./hr. at 14 psig. Exhausting to 4" HgA, turbine drives a generator through a Lufkin Model N1600C gearbox. Generator is an Ideal Type SAB horizontal bru more info...

General Electric Steam Turbine-Generator. 66,086 kW rated straight condensing steam turbine and an ...

 General Electric Steam Turbine-Generator. 66,086 kW rated straight condensing steam turbine and an ...

Stock# 48321001

Used- General Electric Steam Turbine-Generator. 66,086 kW rated straight condensing steam turbine and an 80,300 kVA rated generator, including its auxiliary systems and the condenser system. Condenser is a Graham water cooled condenser with a duty of 434.83 x 106 btu/lb, exhaust pressure of 2.24” HgA and turbine exhaust flow of 481,020 lb./hr. The inlet steam conditions are 850psig/825F and the inlet is sized for a guaranteed flow of 573,334 pph. The max expected flow (not guaranteed) is 641,446 pph of steam flow. The turbine inlet flange is 12”-900# and is oversized such that it could be upgraded to pass up to 660,000 pph of 850psig/825FF steam or an increase of 15% increase over design, if needed for reapplication. The 641,446 pph “expected: flow rating is at “valves wide open”. The generator is a GE H2 cooled, 80,300 kVA, 13,800 v, 2 pole generator with a .85 PF and a .56 short circuit ration. Rating is based on a 30psig H2 pressure, with a 115F H2 temperature and a 100F cooling water temperature. Based on the GE generator inspection report from 2013 this generator has modern 18Mn-18Cr retaining ring material to meet the reliability and insurance company requirements. Graham Manufacturing 58,691 square foot surface area condenser. Bently Nevada 3300 series probes and devices for monitoring alarm and trip funtions. New GE EX2100e digital control system. Built in 1991, shipped in 1992, and major overhaul in 2013.

KW: Mfr: General Electric RPM: Volts:
VIEW ITEM ADD TO CART

Used- Dresser-Rand/Murray Steam Turbine, Model RD6M. 3507 kW

Used- Dresser-Rand/Murray Steam Turbine, Model RD6M. 3507 kW

Stock# 47317001

Used- Dresser-Rand/Murray Steam Turbine, Model RD6M. 3507 kW of power at 5250 RPM, using 60,000 lb./hr. steam at 390 psig and 446 deg. F. With a controlled extraction of 31,900 lb./hr. at 14 psig. Exhausting to 4" HgA, turbine drives a generator through a Lufkin Model N1600C gearbox. Generator is an Ideal Type SAB horizontal brushless synchronous rated 4875 KVA, 3900 KW, 1800 RM, 0.8 P.F. 3Phase, 60 Hz, 4160 Volts with TEWAC enclosure. Generator control unit consists of a Woward DG505E governor, DSM synchronizer, real power sensor, voltage regulator system, panalarm annunciator. Mfg. 1997.

KW: 3507 Mfr: Dresser RPM: 1800 Volts: 4160
VIEW ITEM ADD TO CART
  • General Electric Steam Turbine-Generator. 66,086 kW rated straight condensing steam turbine and an ...

    Used- General Electric Steam Turbine-Generator. 66,086 kW rated straight condensing steam turbine and an 80,300 kVA rated generator, including its auxiliary systems and the condenser system. Condenser is a Graham water cooled condenser with a duty of 434.83 x 106 btu/lb, exhaust pressure of 2.24” HgA and turbine exhaust flow of 481,020 lb./hr. The inlet steam conditions are 850psig/825F and the inlet is sized for a guaranteed flow of 573,334 pph. The max expected flow (not guaranteed) is 641,446 pph of steam flow. The turbine inlet flange is 12”-900# and is oversized such that it could be upgraded to pass up to 660,000 pph of 850psig/825FF steam or an increase of 15% increase over design, if needed for reapplication. The 641,446 pph “expected: flow rating is at “valves wide open”. The generator is a GE H2 cooled, 80,300 kVA, 13,800 v, 2 pole generator with a .85 PF and a .56 short circuit ration. Rating is based on a 30psig H2 pressure, with a 115F H2 temperature and a 100F cooling water temperature. Based on the GE generator inspection report from 2013 this generator has modern 18Mn-18Cr retaining ring material to meet the reliability and insurance company requirements. Graham Manufacturing 58,691 square foot surface area condenser. Bently Nevada 3300 series probes and devices for monitoring alarm and trip funtions. New GE EX2100e digital control system. Built in 1991, shipped in 1992, and major overhaul in 2013.

    VIEW ITEM Add to Cart
  • Used- Dresser-Rand/Murray Steam Turbine, Model RD6M. 3507 kW

    Used- Dresser-Rand/Murray Steam Turbine, Model RD6M. 3507 kW of power at 5250 RPM, using 60,000 lb./hr. steam at 390 psig and 446 deg. F. With a controlled extraction of 31,900 lb./hr. at 14 psig. Exhausting to 4" HgA, turbine drives a generator through a Lufkin Model N1600C gearbox. Generator is an Ideal Type SAB horizontal brushless synchronous rated 4875 KVA, 3900 KW, 1800 RM, 0.8 P.F. 3Phase, 60 Hz, 4160 Volts with TEWAC enclosure. Generator control unit consists of a Woward DG505E governor, DSM synchronizer, real power sensor, voltage regulator system, panalarm annunciator. Mfg. 1997.

    VIEW ITEM Add to Cart
Cash Icon
Surplus Equipment?

We pay "Top Dollar" for your idle process equipment! Fill out our form and our buying team will get back to you.

SELL YOUR EQUIPMENT
Search Icon
Browse Inventory

View our entire process equipment inventory online or visit our location for an equipment inspection.

View Inventory
Phone Icon
Contact Us

Email or call us to speak with an equipment specialist to answer any machinery questions you may have.

630-350-2200